3 Calibration Functions User Manual Test Program SITEST 3.9 Calibration of the RV Nozzle Changer Software Version 405.xx Issue 01/99 3 - 24

User Manual Test Program SITEST 3 Calibration Functions
Software Version 405.xx Issue 01/99 3.9 Calibration of the RV Nozzle Changer
3 - 23
● Click on the
Nozzle data...
button.
A comparison of the setpoint values versus the actually determined values in x and y-directions is dis-
played on the screen for each garage of the selected magazine.
Additionally, the z-position determined is displayed for the currently selected magazine.
● If you wish to check whether the calibration was successful, be sure to first save the calibration data
proceeding as described in chapt. 1, section 1.7, and then return to the "RV nozzle changer" display
after the save is completed.
● Click on the
Garage number...
button.
The input box for entering the garage number opens.
● Enter the desired garage number and confirm your entry by clicking on
Accept
.
● Click on the
Return
button. The nozzle is returned to the selected garage.
● Next, click on the
Pick up
button. The nozzle is removed from the garage.
● Click on the
Dispose of nozzle
button. The nozzle is dropped into the reject box.
● Click on the icon to return to the main view.
3 Calibration Functions User Manual Test Program SITEST
3.9 Calibration of the RV Nozzle Changer Software Version 405.xx Issue 01/99
3 - 24

User Manual Test Program SITEST 3 Calibration Functions
Software Version 405.xx Issue 01/99 3.10 Calibration of the Flip-Chip Camera (SIPLACE 80F4/80F5)
3 - 25
3.10 Calibration of the Flip-Chip Camera
(SIPLACE 80F
4
/80F
5
)
● Carry out the preparatory steps proceeding as described in section 3.1.
● In the "IC head" display (see Fig. 0.3.6) click on the icon to switch to the "Flip-chip camera"
display.
Fig. 3.10.1 "Flip-chip camera" Display
Overview of the functions:
– Calibr. flip-chip camera to calibrate the Flip-Chip camera
– Illumination values... to display the illumination values
(Normally, the illumination values do not
need to be changed.
Changing the values in a non-expert manner will lead to incorrect
calibration results).
– Display camera coefficient... to display the Flip-Chip camera values determined
– Display focus position... to display the camera position and focus height determined