3 Calibration Functions User Manual Test Program SITEST
3.9 Calibration of the RV Nozzle Changer Software Version 405.xx Issue 01/99
3 - 24
User Manual Test Program SITEST 3 Calibration Functions
Software Version 405.xx Issue 01/99 3.10 Calibration of the Flip-Chip Camera (SIPLACE 80F4/80F5)
3 - 25
3.10 Calibration of the Flip-Chip Camera
(SIPLACE 80F
4
/80F
5
)
Carry out the preparatory steps proceeding as described in section 3.1.
In the "IC head" display (see Fig. 0.3.6) click on the icon to switch to the "Flip-chip camera"
display.
Fig. 3.10.1 "Flip-chip camera" Display
Overview of the functions:
Calibr. flip-chip camera to calibrate the Flip-Chip camera
Illumination values... to display the illumination values
(Normally, the illumination values do not
need to be changed.
Changing the values in a non-expert manner will lead to incorrect
calibration results).
Display camera coefficient... to display the Flip-Chip camera values determined
Display focus position... to display the camera position and focus height determined
3 Calibration Functions User Manual Test Program SITEST
3.10 Calibration of the Flip-Chip Camera (SIPLACE 80F4/80F5) Software Version 405.xx Issue 01/99
3 - 26
Click on the
Calibr. flip-chip camera
button.
The calibration of the Flip-Chip camera is now performed.
If you wish to view the values determined after the completion of the calibration procedure, click on the
Display camera coefficient...
button.
If you wish to view the values for the camera position and focus height, click on the
Display focus
position...
button.
NOTE
The x and y-values of the current camera position are also displayed in the "Camera position" field.
Click on the icon to return to the main view.