00191332-01.pdf - 第150页
4 Mapping User Manual Test Program SITEST Software Version 405.xx Issue 01/99 4 - 2

User Manual Test Program SITEST 4 Mapping
Software Version 405.xx Issue 01/99
4 - 1
4 Mapping
WARNING
The gantries will be moving during the performance of the mapping function described in this section.
Prior to the execution of this function make sure that neither any part of your body nor any objects are in the
traversing range of the gantries -
DANGER OF INJURY
.
4

4 Mapping User Manual Test Program SITEST
Software Version 405.xx Issue 01/99
4 - 2

User Manual Test Program SITEST 4 Mapping
Software Version 405.xx Issue 01/99 4.1 Preparatory Steps for the Mapping Operation
4 - 3
4.1 Preparatory Steps for the Mapping Operation
● In the main view click on the
Overall reference run
button to perform a reference run of all gantry and
head axes.
NOTE
For RV and IC mapping a mapping plate with a dark, dull surface must be used.
In the case of dual conveyors, mapping must be performed for the right and left conveyor tracks.
4
CAUTION
!
On no account
must the PCB clamping mechanism be actuated during PCB mapping
. If the glass map-
ping plate for PCB mapping is clamped, it may be damaged so severely, that it cannot be used any more.
4