Service Manual HS60 - 第107页
HS -60 Se rvic e Manu al 4 Ga ntr ies 03/ 200 3 U S Iss ue 4.7 Repl ac ing t he X-a xis sca le (0 0329 316-0 1) 105 4.7. 3 Removin g the X -axis scale 4 F ig . 4 .7 - 1 R ep la ci ng t he X -ax is sc al e Key (1) Increme…
4 Gantries HS-60 Service Manual
4.7 Replacing the X-axis scale (00329316-01) 03/2003 US Issue
104
Æ Loosen the M8x20 hexagon socket-head screw in the hole in the elastomeric spring.
Æ Push the metal sleeve out of the elastomeric spring.
4.6.4 Installing the elastomeric spring
Æ Insert the metal sleeve into the new elastomeric spring.
Æ Use the M8 x 20 hexagon socket-head screw to fix the elastomeric spring.
4.6.5 Settings
None 4
4.7 Replacing the X-axis scale (00329316-01)
4.7.1 Tools and equipment
– Set of DIN 911 Allen keys
– Spacer gauge
– SITEST program
4.7.2 Parts
X-axis scale for the HS-60, from item number 00329316-01 4

HS-60 Service Manual 4 Gantries
03/2003 US Issue 4.7 Replacing the X-axis scale (00329316-01)
105
4.7.3 Removing the X-axis scale
4
Fig. 4.7 - 1 Replacing the X-axis scale
Key
(1) Incremental encoder, X-axis
(2) 2 x M3 x 8 hexagon socket-head screws
(3) 11 x M2.5 x 5 hexagon socket-head screws with washers
(4) Scale, X-axis
(5) Proximity switch B1 and B2 for the X-axis
(6) Head mount
(7) Elastomeric spring
A Stop for the scale on the bars 4
Æ Switch the placement system off and secure it to prevent switching on again as described in
Section 4.4
, page 100 onward.
DANGER POWERFUL MAGNETIC FIELD 4
Always follow the special safety instructions when working in the vicinity of powerful magnetic
fields (see Section 4.5, page 101 onward). 4
Æ Loosen two M3 x 8 hexagon socket-head screws (item 2 in Fig. 4.7 - 1) to remove the incre-
mental encoder for the X-axis (item 1 in Fig. 4.7 - 1
).

4 Gantries HS-60 Service Manual
4.7 Replacing the X-axis scale (00329316-01) 03/2003 US Issue
106
Æ Loosen the eleven M2.5 x 5 hexagon socket-head screws (item 3 in Fig. 4.7 - 1) with washers.
Æ Move the head mount (item 6 in Fig. 4.7 - 1) across as far as the elastomeric spring (item 7 in
Fig. 4.7 - 1
) in order to prevent any damage to proximity switches B1 and B2 (item 5 in Fig. 4.7
- 1).
Æ Remove the scale (item 4 in Fig. 4.7 - 1).
4.7.4 Installing the X-axis scale
Æ Carefully insert the scale.
CAUTION 4
Do not touch the incremental tracks with bare fingers. 4
Æ Loosely tighten the eleven M2.5 x 5 hexagon socket-head screws with washer.
Æ Push the scale along the bars as far as the stop (item A in Fig. 4.7 - 1)
Æ Tighten the M2.5 x 5 hexagon socket-head screws.
Æ Use the feeler gauge to set the 0.4 mm gap between the incremental encoder and scale.
Æ Use the two M3x8 hexagon socket-head screws (item 2 in Fig. 4.7 - 1) to fix the incremental
encoder (item 1 in Fig. 4.7 - 1
) to the X-axis.
4.7.5 Settings
Æ Set and calibrate the collect&place head and gantry axes using the SITEST program.