20
WARNING 2
The system is electrically driven. When electrical devices are in use, certain parts carry dangerous
voltage levels.
Æ Switch off at the main switch and disconnect the placement system from the power supply be-
fore carrying out any work on live components.
Æ Lock the systems as described in Section 2.8, page 62.
There is a risk of death, severe injury and/or considerable damage to equipment if these instruc-
tions are not followed.
2.1.5.3 Safety of plant and equipment
Æ Never make changes, however minor, unless you are totally aware of the effect they will have
on the overall functioning of the system.
Æ The stations must always be set up, retooled and maintained by appropriately trained person-
nel.
Æ Only use SIEMENSDEMATIC original spare parts and authorized accessories. The use of
other parts will affect safety and will invalidate the liability for any consequential damage.
Æ Do not make modifications to the safety equipment. In particular, NEVER bypass circuit-break-
ers or remove safety devices.
2.1.6 Safety instructions for laser units
Permission to operate components that are classified as lasers is withdrawn if
mechanical damage to the unit is observed, or
any work is done on the mechanical or electrical parts of the unit.
Even damaged or missing screw locking paint on laser components (e.g. cover plates, fas-
teners, adjusting potentiometer) counts as work.
Only SIEMENSDEMATIC AG service engineers, or the machine owner's service engineers
who have been trained by SIEMENSDEMATIC are allowed to replace laser components.
Repairs to laser units are carried out at the SIEMENS DEMATIC factory exclusively.
Service Manual HS-60 2 Operational safety
03/2003 US Issue 2.1 Safety instructions
21
2.1.7 Safety instructions on permanent magnets
Strong permanent magnets are used for the Y-axis linear motor.
DANGER OF DEATH
STRONG PERMANENT MAGNETIC FIELDS INSIDE THE MACHINE 2
The life of persons with passive or active implants such as pacemakers, defibrillators, insulin
pumps etc. is put at risk inside the machine if protective covers are opened.
CAUTION STRONG MAGNETIC FIELDS 2
There is a risk that the strong magnetic fields could corrupt data on data media or credit cards
and check cards.
2.1.8 Important notes on environmentally-friendly disposal of materials
and components
SIPLACE systems are manufactured using only materials and parts that can be easily separated
and disposed of in an environmentally-friendly way. Hazardous materials are not necessary for the
installation, dismantling or operation of the system.
NOTE 2
The owner of the system has sole responsibility for the proper environmentally-friendly disposal
of machines, working materials, consumables and wear parts.
Æ Please observe your national statutory provisions for waste disposal and environmental pro-
tection.
2 Operational safety Service Manual HS-60
2.2 Warning labels 03/2003 US Issue
22
2.2 Warning labels
2.2.1 Warning labels W201, W203, and W204 on the machine
The warning labels are made from soft PVC film, and are abrasion-proof, light-fast and resistant
to water and weathering.
Their design meets the requirements of ISO 3864-2 and ANSI Z535.4.
Fig. 2.2 - 1 Warning labels W201, W202, W203, W204, and W206 on the machine
WARNING 2
Do not use abrasive cleaners or solvents for cleaning warning labels.
Replace any damaged or illegible warning or notice labels.