Service Manual HS60 - 第284页
7 DL M2 Co llec t &P lace Head H S-6 0 S erv ic e Manu al 7.9 R epl ac ing the valve posit ion ing dri ve for th e plac ement (0036 8075 -01) a nd re ject circ uits (00367 768-0 1) 03/20 0 3 US Is sue 282 7 F ig. 7. …

HS-60 Service Manual 7 DLM2 Collect&Place Head
03/2003 US Issue 7.9 Replacing the valve positioning drive for the placement (00368075-01) and reject circuits (00367768-01)
281
7.9 Replacing the valve positioning drive for the placement
(00368075-01) and reject circuits (00367768-01)
7.9.1 Tools and equipment
– Set of DIN 911 Allen keys
– Set of Phillips screwdrivers
– SITEST program
– Feeler gauge, item no. 00325445-01
7.9.2 Parts
Valve positioning drive, placement circuit, item no. 00368075-01 (Pos. 1 in Fig. 7.9 - 1)
Valve positioning drive, reject circuit, item no. 00367768-01 (Pos. 2 in Fig. 7.9 - 1
) 7
7.9.3 Dismantling the valve positioning drive
Æ Remove the collect&place head from the head mount (see Section 7.5.3, page 263).
Æ Undo the two M2x6 Phillips screws on the ribbon cable clamp (items 3 and 4 in Fig. 7.9 - 1).
Æ Undo the M3x10 hexagon socket-head screw (item 4 in Fig. 7.9 - 1).
Æ Carefully remove the valve positioning drive (item 1 or 2 in Fig. 7.9 - 1).

7 DLM2 Collect&Place Head HS-60 Service Manual
7.9 Replacing the valve positioning drive for the placement (00368075-01) and reject circuits (00367768-01) 03/2003 US Issue
282
7
Fig. 7.9 - 1 Replacing the valve positioning drive
Key to Fig. 7.9 - 1
(1) "Placement circuit" valve positioning drive
(2) "Reject circuit" valve positioning drive
(3) Back part of the collect&place head
(4) M3x10 hexagon socket-head screw
(5) Parallel pins, 2 x per drive
7

HS-60 Service Manual 7 DLM2 Collect&Place Head
03/2003 US Issue 7.9 Replacing the valve positioning drive for the placement (00368075-01) and reject circuits (00367768-01)
283
7.9.4 Fitting the valve positioning drive
Æ Insert the valve positioning drive, making sure that it is seated correctly on the parallel pins.
Æ Loosely tighten the hexagon socket-head screw.
Æ Use the cable clamp assemblies (items 2, 3, and 4 in Fig. 7.9 - 2) to fix the ribbon cables in
position, ensuring that the ribbon cables are not squashed.
CAUTION 7
Check that the ribbon cables (item 1 and 2 in Fig. 7.9 - 2
) are laid correctly. The ribbon cable
(item 2 in Fig. 7.9 - 2
) from the valve adjustment unit to the reject station (item 6 in Fig. 7.9 -
2) must run outside the hole (item 5 in Fig. 7.9 - 2), otherwise it will be damaged when the
collect&place head is fitted on the head mount. 7
7
7
7
7
7
7
7
7
7
7
Key to Fig. 7.9 - 2
(1) Flat ribbon cable for the ’Placement’ valve adjustment unit
(2) Flat ribbon cable for the ’Reject circuit’ valve adjustment unit
(3) Cable clamp assembly
(4) Cable clamp assembly
(5) Hole
(6) ’Placement’ valve positioning drive
(7) ’Reject circuit’ valve positioning drive
7