Service Manual HS60 - 第285页
HS -60 Se rvic e Ma nual 7 DLM2 Co l lect&Plac e Head 03/ 2003 US Issu e 7.9 Repl acin g the val ve pos i ti onin g drive for th e plac ement ( 0036 8075-0 1) and r eje ct circ uits (0 0367 768-0 1) 283 7.9. 4 Fittin…

7 DLM2 Collect&Place Head HS-60 Service Manual
7.9 Replacing the valve positioning drive for the placement (00368075-01) and reject circuits (00367768-01) 03/2003 US Issue
282
7
Fig. 7.9 - 1 Replacing the valve positioning drive
Key to Fig. 7.9 - 1
(1) "Placement circuit" valve positioning drive
(2) "Reject circuit" valve positioning drive
(3) Back part of the collect&place head
(4) M3x10 hexagon socket-head screw
(5) Parallel pins, 2 x per drive
7

HS-60 Service Manual 7 DLM2 Collect&Place Head
03/2003 US Issue 7.9 Replacing the valve positioning drive for the placement (00368075-01) and reject circuits (00367768-01)
283
7.9.4 Fitting the valve positioning drive
Æ Insert the valve positioning drive, making sure that it is seated correctly on the parallel pins.
Æ Loosely tighten the hexagon socket-head screw.
Æ Use the cable clamp assemblies (items 2, 3, and 4 in Fig. 7.9 - 2) to fix the ribbon cables in
position, ensuring that the ribbon cables are not squashed.
CAUTION 7
Check that the ribbon cables (item 1 and 2 in Fig. 7.9 - 2
) are laid correctly. The ribbon cable
(item 2 in Fig. 7.9 - 2
) from the valve adjustment unit to the reject station (item 6 in Fig. 7.9 -
2) must run outside the hole (item 5 in Fig. 7.9 - 2), otherwise it will be damaged when the
collect&place head is fitted on the head mount. 7
7
7
7
7
7
7
7
7
7
7
Key to Fig. 7.9 - 2
(1) Flat ribbon cable for the ’Placement’ valve adjustment unit
(2) Flat ribbon cable for the ’Reject circuit’ valve adjustment unit
(3) Cable clamp assembly
(4) Cable clamp assembly
(5) Hole
(6) ’Placement’ valve positioning drive
(7) ’Reject circuit’ valve positioning drive
7

7 DLM2 Collect&Place Head HS-60 Service Manual
7.9 Replacing the valve positioning drive for the placement (00368075-01) and reject circuits (00367768-01) 03/2003 US Issue
284
7
Fig. 7.9 - 2 Laying the ribbon cables for the valve adjustment drives