Service Manual HS60 - 第292页

7 DL M2 Co llec t &P lace Head H S-6 0 S erv ic e Manu al 7. 11 R e pl acin g l ig ht ba rr ie r ’ Z- a xi s up ’ ( 0 034 72 97 -01 ) 03/ 2 003 U S I ss ue 290 7.10.4 F ittin g the i ntermedia te dist ributi on board…

100%1 / 348
HS-60 Service Manual 7 DLM2 Collect&Place Head
03/2003 US Issue 7.10 Replacing the intermediate distribution board (00330648-05)
289
Æ Carefully remove the hose from the pressure sensor (see U4 in Fig. 7.10 - 2).
Æ Remove the following plugs from their sockets on the board (see Fig. 7.10 - 2 on page 289).
Æ Remove the intermediate distribution board.
7
Fig. 7.10 - 2 Sockets on the intermediate distribution board
X1 Ribbon cable at X14 on the head board
X2 Ribbon cable at X13 on the head board
X3 Motor / tacho connection for the Z-axis
X4 Measuring system connection for the Z-axis
X5 Motor connection for the star axis
X6 Connection for the "Forced air unit" valve
X7 Measuring system connection for the DP-axis
X10 Connection for the "Z-axis up" light barrier (adjustment unit)
X11 Connection for the "Z-axis down" light barrier
X12 Measuring system connection for the star axis
Tab. 7.10 - 1Sockets on the intermediate distribution board
7 DLM2 Collect&Place Head HS-60 Service Manual
7.11 Replacing light barrier ’Z-axis up’ (00347297-01) 03/2003 US Issue
290
7.10.4 Fitting the intermediate distribution board
Æ Restore connections X1 ... X12 as described in Table 7.10 - 1.
Æ Push the hose onto the pressure sensor tube (see item 4 in Fig. 7.10 - 1).
Æ Fix the intermediate distribution board in place (see item 2 and 3 in Fig. 7.10 - 1).
Æ Fix the protective cover to the head.
Æ Switch the placement system on and start it up.
7.10.5 Settings
No settings are required. 7
7
7.11 Replacing light barrier ’Z-axis up’ (00347297-01)
7.11.1 Tools and equipment
Set of DIN 911 Allen keys
Set of Phillips screwdrivers
SITEST program
7.11.2 Parts
Light barrier ’Z-axis up’, item no. 00347297-01 7
7.11.3 Dismantling the ’Z-axis up’ light barrier
Æ Switch the placement system off and secure it to prevent switching on again as described in
Section 7.4
, page 261.
Æ Remove the plug from socket X10 on the intermediate distribution board (see item 10 in Fig.
7.2 - 5
, page 254).
Æ Undo the two M2.0x4 hexagon socket-head screws (see item 1 in Fig. 7.11 - 1) and remove
the ribbon cable clamp (see item 2 in Fig. 7.11 - 1
).
Æ Undo the two M1.6x3 Phillips screws (see item 3 in Fig. 7.11 - 1).
Æ Remove the light barrier board (see item 4 in Fig. 7.11 - 1) together with its cable.
HS-60 Service Manual 7 DLM2 Collect&Place Head
03/2003 US Issue 7.11 Replacing light barrier ’Z-axis up’ (00347297-01)
291
7
Fig. 7.11 - 1 Replacing the ’Z-axis uplight barrier board
Key to Fig. 7.11 - 1
(1) 2 x M2.0x4 hexagon socket-head screw
(2) Cable clamp assembly, flat
(3) 2 Phillips screws (1.6x3)
(4) Light barrier board ’Z-axis up’
7.11.4 Fitting the ’Z-axis up’ light barrier
Æ Use the two M1.6x3 Phillips screws (see item 3 in Fig. 7.11 - 1) to fix the light barrier board
(see item 4 in Fig. 7.11 - 1
) in place.
Æ Connect the ribbon cable plug to socket X10 on the intermediate distribution board (see
item X10 in Fig. 7.2 - 5
).
Æ Use the ribbon cable clamp (see item 2 in Fig. 7.11 - 1) and the two hexagon socket-head
screws (see item 1 in Fig. 7.11 - 1
) to fix the ribbon cables.
CAUTION 7
Make sure that the ribbon cable is not squashed in the guide channel.
Make sure to push the folded part of the flat ribbon cable for the ’Z-axis up’ light barrier back under
the illumination board. 7