7 DLM2 Collect&Place Head HS-60 Service Manual
7.14 Replacing the forced air unit (00367793-01) 03/2003 US Issue
300
7.14 Replacing the forced air unit (00367793-01)
7.14.1 Tools and equipment
Set of DIN 911 Allen keys
Open-ended spanner, size 8
7.14.2 Parts
Forced air unit / DLM2, item no. 00367793-01 7
7.14.3 Dismantling the forced air unit
Æ Remove the cable plug from socket X6 on the intermediate distribution board.
Æ Detach the black compressed air hose from the plug-in coupling on the vacuum distributor.
HS-60 Service Manual 7 DLM2 Collect&Place Head
03/2003 US Issue 7.14 Replacing the forced air unit (00367793-01)
301
Fig. 7.14 - 1 Dismantling the forced air unit
Key to Fig. 7.14 - 1
(1) Forced air unit / DLM2
(2) To the "Placement circuit" compressed air tube and the compressed air sensor on the
intermediate distributor
(3) To the "Reject circuit" compressed air tube
(4) M3x20 hexagon socket-head screw
(5) SW8 union nut for the compressed air connection
(6) "Forced air" micro-relay valve
7
Æ Dismantle the intermediate distributor as described in Section 7.10.3, page 288.
Æ Detach the compressed air sensor.
Æ Detach the compressed air hose for the placement position (item 2 in Fig. 7.14 - 1) from the
"Placement circuit" compressed air tube.
7 DLM2 Collect&Place Head HS-60 Service Manual
7.14 Replacing the forced air unit (00367793-01) 03/2003 US Issue
302
Æ Detach the compressed air hose for the reject position (item 3 in Fig. 7.14 - 1) from the "Reject
circuit" compressed air tube.
Æ Undo the M3x20 hexagon socket head screw.
Æ Remove the forced air unit (item 1 in Fig. 7.14 - 1).
Æ Loosen the union nut (item 5 in Fig. 7.14 - 1) and detach the compressed air supply hose.
7.14.4 Fitting the forced air unit
Æ Connect the hoses.
Æ Use the hexagon socket-head screw to fix the forced air unit.
Æ Connect the plug to socket X6 on the intermediate distribution board (see Fig. 7.5 - 1.
CAUTION 7
Risk of injury from the compensating tube when the hose is pushed onto the measuring tube.7
Æ Fit the intermediate distributor.
7.14.5 Settings
Æ No settings are required.