Service Manual HS-60 8 Movable Component Changeover Table
03/2003 US Issue 8.5 Resolving problems
343
Æ Clock / transport the first component into the pick-up position. VISUALLY CHECK the front of
the module to see if all tapes move smoothly into the empty-tape duct.
DANGER
The SITEST program may only be started by personnel who have been trained in its use by Sie-
mens and are therefore authorized to do so.
The cutter must also be completely assembled for work with the SITEST program.
The changeover table must be moved into the machine and correctly connected.
The component changeover table, which has been moved into the machine, must always be com-
pletely equipped with feeder modules or dummy modules (see User Manual and Service Manual,
chapters "Operational Safety").
The key switch remains locked (= normal mode = position "0").
8
Æ After exchanging the cable for the component table and/or the communications unit:
Note the DANGER text regarding the SITEST program.
Load the SITEST program and check the component table functions.
Æ Exit the SITEST program.
Æ Start the placement process.
8 Movable Component Changeover Table Service Manual HS-60
8.5 Resolving problems 03/2003 US Issue
344