Getting started 1 - 8 Vision2007 4.10 User Manu al Rev 01 This part allows you to change some gray level calibration param eters. Head <3D: ...> : parameters for 3D ac quisition chain. Head <External camera: ...…

100%1 / 412
Getting started
Vision 2007 4.10 User Manual Rev 01 1 - 7
1.3.2.2 Acquisition head tab
The Acquisition head tab display the configuration of all acquisition chains. You can
choose the frame grabber, the camera, and some calibration parameters.
You must choose the frame grabber you have in your computer. An image of the avail-
able frame grabber is displayed.
You must choose the camera you have in the acquisition head. An image of the available
camera is displayed.
AOI system configuration
Getting started
1 - 8 Vision2007 4.10 User Manual Rev 01
This part allows you to change some gray level calibration parameters.
Head <3D: ...>: parameters for 3D acquisition chain.
Head <External camera: ...>: External DataMatrix reader system parameters.
AOI system configuration
Getting started
Vision 2007 4.10 User Manual Rev 01 1 - 9
1.3.2.3 Axis/Conveyor tab
Conveyor type (A): determine the conveyor type:
Single manual: only 2 axes,
Single: 3 axes (std Vi-3000),
Double upstream,
Double downstream.
Conveyor Width (B): set the maximum conveyor width. This parameter was in the main-
tenance mode before but now it is the only way to change it. Normally this width is cor-
rectly set in the factory so you do not have to change it.
Speedy SMEMA (C): set the SMEMA type:
If Speedy SMEMA equals to true, than acknowledge for board received will be send
to upstream system when board arrives on AOI system entry sensor.
If Speedy SMEMA equals to false, than acknowledge for board received will be send
to upstream system when board arrives on AOI system stop sensor.
Conveyor time out (D): if the board is not loaded or unloaded during this time, the soft-
ware return a conveyor error.
Tempo after unclamp (E): this new parameter allows the user to add a temporization
between the moment when the card is unclamped after inspection, and the moment
when it is being conveyed to the exit.
A
B
C
D
E
AOI system configuration