VI User Manual - 第336页

Optimization 12 - 18 Vision 2007 4.10 User Manual Re v 01 Formulas This time cal culation takes in a ccount the rate of success of the lin k. It indicates fastest link which validate a component with the highest score. I…

100%1 / 412
Optimization
Vision 2007 4.10 User Manual Rev 01 12 - 17
12.3.6.2 Interpretation
In Customer library, tick the check boxes of the Remove (A) column to remove
unused links.
In
Standard library, tick the check boxes of the Add (B) column to add models
which validate components. The model name will just change when you save the
library. (for this interface it will be the standard name)
You can access to more details if you double click on a model from the
Customer
or the Standard library.
In
Select show model (C) section, you can display all the models from the custom-
er library or only models which are never used: models which never pass any com-
ponents.
These modifications will modify the ADC library organization.
A
B
C
Auto Defect Correction (ADC)
Optimization
12 - 18 Vision 2007 4.10 User Manual Rev 01
Formulas
This time calculation takes in account the rate of success of the link.
It indicates fastest link which validate a component with the highest score.
It is used to sort links in the ADC library.
If you let the cursor in the center position, the sort is not a slower link but with a higher
occurrence will be in the 1st position.
Number of times this link was the best (higher score)
Number of components tested with the same Jedec
% of winner =
x 100
Nb winner % winner Nb pass Score average
C1005 20 4% 120
Σ
(scores) / 120
C1005A 300 60% 360
Σ
(scores) / 360
C1005B 180 36% 200
Σ
(scores) / 200
None 20 4 %
500 100 0<…<1500
120
360
200
Example: 500 components C1005 tested
Sum of the scores when a component passes with this link
Number of times the link passes
Score average =
Sum of the inspection times for this link
Number of times this link was the winner
Time =
Example: 500 components C1005 tested
Nb winner Time
C1005 20
Σ
(scores) / 20
C1005A 290
Σ
(scores) / 290
C1005B 170
Σ
(scores) / 170
None 20
500
500
500
500
Auto Defect Correction (ADC)
Optimization
Vision 2007 4.10 User Manual Rev 01 12 - 19
12.3.6.3 ADC library sorting
Tick the check box (A) to change the ADC library arrangement. If not, links from the
standard library will be added at the end.
In
Sort (B) section, move the cursor to the Time indication to have fastest links in
the 1st position. Move the cursor to the
Accuracy indication to have links with high-
est scores in the 1st position.
A
B
Auto Defect Correction (ADC)