.ini files A - 2 Vision 20 07 4.10 User Manual Rev 01 A.1 General section [File] Exist=1 [VERSION] Number=83 You should not modify these keys. These sections are used by Vision 2007 to det ermine the version number of th…

100%1 / 412
Vision 2007 4.10 User Manual Rev 01 A - 1
Appendix A
.ini files
The DefaultValue.ini file contains default values of maintenance, library, .tst file and Cognex console. It is
located in Vision2007.exe folder (e.g. C:\vit\config\defaultvalue.ini). Editing this file allows you to customize
the software.
The .ini file values are also used as default parameters when you create new objects in the .tst file or in the
library for example.
The DefaultValue.ini file is divided into different sections. The sections names are bracketed. Each section
contains one or more keys that identify the default values. It is very important not to change the sections names
and the keys.
You can edit the .ini file using windows Notepad or any text editor. Each default value has a validity range. If
the value you set in the .ini file is out of this range, Vision 2007 automatically resets it to the initial default value
when it loads the file.
The values stored in the .ini file are loaded each time you start Vision 2007. If the file is not found, a new one
will be created with the initial default values of the software.
You can reload the values manually using the main frame menu.
Go in Process menu and select Load .ini file.
Units
Lengths are set in millimeters,
Angles in degrees,
Duration in seconds.
The Default button present in almost windows reloads the .ini file values for the active window.
.ini files
A - 2 Vision 2007 4.10 User Manual Rev 01
A.1 General section
[File] Exist=1
[VERSION] Number=83
You should not modify these keys.
These sections are used by Vision 2007 to determine the version number of the .ini file.
If the version number is obsolete, Vision 2007 will complete the .ini file with the missing keys
and sections.
.ini files
Vision 2007 4.10 User Manual Rev 01 A - 3
A.2 General software behavior
INI section: [Cognex console]
Keys A and B enable or disable the scroll bars of the Cognex console.
INI section: [External communication]
INI section: [Axes]
Mark Key name Initial value Min value Max value
A Activate horizontal scroll bar(0,1) 1 0 1
B Activate vertical scroll bar(0,1) 1 0 1
Mark Key name Initial value Min value Max value
A Prog_ID
Optional: this key refers to an external communication module.
Mark Key name Initial value Min value Max value
A
Mapping File
calib.map