PSV5000_OwnersManual - 第105页
W orkspace , Head and Gant ry Sock et A dapt ers and Actuat io n PSV5000 O wner ’s M anual - 101 - WARNING : Elec tric shock haza rd! Op ening any access d oors while the pow er is ON can be danger ous ev en when st …

Maintenance ■ Workspace, Head and Gantry
- 100 - Data I/O ■ 096-0465-001C
Figure 58: The Socket Opener Pressure Control knob with built-in
gauge on the Power Panel.
4. At the Power Panel on the left side, adjust the air pressure up or
down as desired by pulling the collar on the black knob out and then
rotating it.
5. Push the collar back in.
Note: The lowest pressure setting that opens the sockets all the way
reliably is recommended.
6. Cycle the sockets as before to verify the change in action.
7. Repeat if necessary.
Note: If Socket Actuator problems persist, set the actuator speed (refer to
the next heading).
ADJUSTING THE SOCKET ACTUATOR SPEED ON THE PROGRAMMERS
THE SOCKET ACTUATOR SPEED WAS SET AT THE FACTORY AND
SHOULD NOT NEED ADJUSTMENT. If it is determined that adjustment
is necessary, this procedure requires a Data I/O trained technician since
it requires having an access door open while the machine power is on.
REQUIREMENTS
• Programmer air pressure must be correct. See previous heading.
• Small flat screw driver.
TO ADJUST THE SPEED OF THE SOCKET ACTUATORS:
1. Ensure that power and air are connected and ON, and a Socket
Adapter is installed on the target programmer.
2. At the Gantry window, click the label for a programmer with the
adapter installed. Probe 1 will stop over socket 1.

Workspace, Head and Gantry Socket Adapters and Actuation
PSV5000 Owner’s Manual - 101 -
WARNING: Electric shock hazard! Opening any access doors while
the power is ON can be dangerous even when steps instruct you to
do so. Use extreme caution and do not touch any electronic
equipment except as directed.
3. Open the access door nearest the target programmer and locate the
in-line air flow control for the up (sockets closed) position. Refer to
Figure 4-3.
Figure 59: Actuator flow controls (arrow). The lower one (that the
screwdriver is at) sets the UP speed. FlashCORE programmers
shown here.
4. Adjust the appropriate flow control 1/2 to 1 revolution clockwise
for slower action, or counter-clockwise for faster action.
5. Close the access door, and clear the door open warning on the
monitor.
6. At the Actuate tab of the Gantry window, click the Actuate Socket
switch to ON while listening and watching the opener. If it is too
fast it will produce a louder noise than optimum when it operates.
If it is too slow it will look slow.
7. Click Actuate Socket OFF.
8. Adjust the flow controls as necessary and repeat the test.
9. Perform the same procedure for the other flow control if necessary.

Maintenance ■ Workspace, Head and Gantry
- 102 - Data I/O ■ 096-0465-001C
Cleaning the PSV5000 Machine
GENERAL MACHINE CLEANING
General cleaning should be performed on a weekly basis. General
cleaning includes, but is not limited to, the following listed item.
WARNING: Vision hazard! Pressurized air or debris blown into
the eyes or skin could cause bodily damage. Always use care and
wear protective eye goggles when cleaning with pressurized air.
1. Remove all dropped devices, debris, and other materials from all
working areas.
2. With air and power OFF, remove all devices and materials that may
have fallen inside the machine.
3. Use dry, compressed air to remove all dust and debris from the
work surface and from under the machine.
4. Dust the safety doors, inside and outside, with an antistatic
cleaner.
5. Wipe the top and side panels to remove grease, fingerprints, and
dust.
6. Dust the top surfaces of the input/output modules.
CLEANING THE CAMERA COVER
Fingerprints and excessive amounts of dust or other residue on the
camera cover will affect the alignment.
If the camera can’t provide a good image, it may be an indicator that the
cover needs cleaning.
Wipe the camera glass in the work surface with a soft cloth and isopropyl
alcohol.