 Pick and Place Prob e  R eplacing a PNP P rob e Assembly PSV5000 O wner ’s M anual - 115 - CAU TIO N: Po ssi bl e Mach ine Dam age! The P NP head an d gantr y can b e dam aged by pushing or pul ling it im pro perl y. …

100%1 / 176
Maintenance Pick and Place Probe
- 114 - Data I/O ■ 096-0465-001C
A spare Probe Assembly
comes with the
Self-Service Spares Kit.
Figure 69: The Y-axis gantry ball screw and guide block, with cover
(left) and without.
3. Apply grease directly to the linear guide. Wipe off any excess.
4. Lubricate the Y-axis ball screw after
wiping off the old grease. Directly
apply new grease to the ball screw
sparingly. Wipe off any excess.
5. Replace all guards and shields.
Replacing a PNP Probe Assembly
Technicians trained on the PSV5000 can remove and re-install a Probe
Assembly if it is damaged or malfunctioning.
Requirement
Metric hex key set (Long set with extended reach is best)
• Spare Probe Assembly
To remove a Probe Assembly
1. End a job and move the PNP head to the PARK position (click System
> Gantry > Tool) to move it to an accessible position.
2. Properly shut down the PSV5000 System; refer to Shutting Down the
PSV5000 System on page 38.
Pick and Place Probe Replacing a PNP Probe Assembly
PSV5000 Owner’s Manual - 115 -
CAUTION: Possible Machine Damage! The PNP head and gantry
can be damaged by pushing or pulling it improperly.
When moving the head, only push or pull by gripping a gantry part and
not the head.
3. Remove the probe from the Probe stem. Refer to Installing the Correct
Probe in the PSV5000 Operator’s Manual.
4. Disconnect the air hose form the vacuum generator (shown in the
figure below) by pushing on the collar while pulling the tubing.
Figure 70: Remove the air line at the One-Touch air connector at
the top of the assembly. Remove bracket fasters (arrows).
5. Remove the bracket with the vacuum generator attached; four
screws; three use 2.5 mm hex key, the back one uses 2 mm hex
key. See Figure 71: .
6. Unplug the ribbon cable from the back of the head assembly by
pulling down on the connector.
Maintenance Pick and Place Probe
- 116 - Data I/O ■ 096-0465-001C
Figure 71: Unplug the ribbon cable from the back.
7. Disconnect the small connect at the top of the assemble by pinching
the clip and pulling up.
Figure 72: Top connector on the P robe Assembly.
8. Remove the four fasteners that hold the Probe Assembly to the PNP
head. Refer to Figure 71: (A long 2.5 mm hex key is required.)
9. Disconnect and remove the Z-axis retention spring (front side of
assembly).
10. Remove two wire connectors from the back of the motor. See Figure
74: .