Maintenance The Laser Module and Shuttle
- 126 - Data I/O ■ 096-0465-001C
3. Wipe the shuttle tips with a damp clothsoapy water is okay. (Do
NOT use alcohols or solvents.)
Laser Marking Fume Extractor
[Laser Marking only] All models with Laser Marking have a fume
extractor. The fume extractor requires some attention as described
below.
START-UP
CAUTION: Possible health hazard! Dust from the main filter may be
expelled on start-up after PSV5000 transportation. Turn the system ON in a room
with appropriate ventilation or wear dust respirator and goggles.
The Fume Extractor starts automatically when the PSV500 Machine is
started (unless the extractor has been manually turned off).
WARNING: Possible health hazard! Lased materials can
contain hazardous toxins in the dust that cause eye and skin damage! DO
NOT use compressed air to remove laser dust or any method that allows the
particulate to be released into the work environment. Wear safety goggles
and disposable protective gloves.
CLEANING THE LASER MODULE AND FUME EXTRACTOR TUBE
The filter extraction tube should be cleaned occasionally for best flow.
Contact Data I/O Customer Support or a local Data I/O approved service
representative.
WARNING: Health hazard! Failure to replace the laser vacuum filters
at the required intervals could create a hazardous operating environment.
WARNING: Hazardous MaterialsPossible health hazard!
This procedure involves exposure to hazardous by-products from the laser
marking process. Some device material may be carcinogenic.
The Laser Module and Shuttle Laser Marking Fume Extractor
PSV5000 Owner’s Manual - 127 -
Perform the following procedure only if you have training regarding laser
etching processes or handling hazardous materials.
Wear safety goggles and disposable protective gloves..
For both these procedures contact Data I/O Customer Support or a local
Data I/O approved service representative.
REPLACING THE FUME EXTRACTOR FILT E RS
TOOLS REQUIRED
sealable plastic bag (approximately .06 M3 [2 cu. ft.])
protective gloves and goggles
a particle (dust) mask
access door key that came with your PSV5000
UpperHand Fume Extractor Operation Manual
To replace the Fume Extractor Filters:
1. Properly shut off the PSV5000 sub-systems and machine power. See
Shutting Down the PSV5000 System on page 38.
WARNING: Possible health hazard! Lased materials can
contain hazardous toxins in the dust that cause eye and skin damage! DO
NOT use compressed air to remove laser dust or any method that allows the
particulate to be released into the work environment.
Some device material may be carcinogenic.
Wear safety goggles and disposable protective gloves.
WARNING: Health hazard! Failure to replace the laser vacuum filters
at the required intervals could create a hazardous operating environment.
2. Wear eye protection and put on disposable protective gloves.
3. Open the front access door.
Maintenance The Laser Module and Shuttle
- 128 - Data I/O ■ 096-0465-001C
Figure 77: The Fume Extractor inside the front of the PSV5000.
4. To continue, see the replacement instructions and part numbers of
the UpperHand pre-filter and main filter in the UpperHand Fume
Extractor Operation Manual (that came with PSV5000).
Figure 78: These four steps show filter replacement. Refer to the
Fume Extractor Operation Manual.
To finish, place the filters and your gloves in the bag and seal the bag and
dispose of as hazardous waste. Close the access door.