PSV5000_OwnersManual - 第146页
Maint enance ■ T ape Output Syst em Main te nance - 142 - Data I/O ■ 096 - 0 465 - 00 1C A T THE S ETU P MENU : • reset Cou nt Stop to desi red amount: Pres s 1, to re - zero the pr esent count Press 2, t hen enter the d…

Tape Output System Maintenance Cleaning the Pressure Seal
PSV5000 Owner’s Manual - 141 -
To clean the Pressure Seal Tape Output System:
1. Turn ON the PSV5000 System power and air.
2. Start TaskLink.
3. Select a job that requires the use of the tape output.
4. Click Run (and Yes or OK to subsequent dialogs), which opens
CH700 automatically.
5. Click Start.
6. Turn on the Tape Output Controller by pushing the red Power
button. Refer to the figure below.
7. At the V-TEK start-up screen, select Setup by pressing the left arrow
button.
Figure 82: Tape Output Module Controller. The arrow points to the
Power On/Off button which is also the Emergency-Stop (for the
Tape-Out Module only!).
8. Configure the Tape Output Controller by setting the following:

Maintenance ■ Tape Output System Maintenance
- 142 - Data I/O ■ 096-0465-001C
AT THE SETUP MENU:
• reset Count Stop to desired amount:
Press 1, to re-zero the present count
Press 2, then enter the desired number, then press the
ENT button.
• select the desired device tape pitch from the Pitch
Selection menu. Then press ENT.
The pitch can be determined by using the pitch setting decal
located on the loading track or the pitch setting guide found at the
front of the TM-50 Taping Module User’s Guide.
AT THE ADVANCE MENU:
• set the number of pockets to advance to 1. Then press
ENT.
AT THE SPEED MENU:
• set the advance speed between 40 to 100 depending on
the device tape width and device size. Then press ENT.
NOTE: Prevent device tape breakage and advancement problems
with narrower tape widths by setting slower speeds— in range
40 to 60.
Higher speeds may cause the devices to be dislodged from the
pockets or may cause the sprocket holes on the tape to rip out.
AT THE JOG MENU
• jog the device tape forward to align the pocket with the
PNP head.
AT THE MODE MENU
• select PSA mode for pressure seal cover tape. An asterisk
indicates the current setting. Then press ESC.
NOTE: The Heat Seal switch should be OFF.
AT THE RUN MENU
• select Run Mode. The run window displays all the

Tape Output System Maintenance Cleaning the Pressure Seal
PSV5000 Owner’s Manual - 143 -
selected setup parameters.
• verify all settings for accuracy.
9. Inspect the PSA seal rollers for build up of grime from the cover tape.
See the figure below.
Figure 83: On the Tape Out Module, the PSA Seal Rollers (arrows)
and Sprocket Idler with O-Rings.
CAUTION: Possible Machine Damage! Do not use solvents other than
alcohol when cleaning the black polyurethane wheels.
10. If grime buildup exists on the PSA Seal rollers—
a. Using a shop towel and alcohol or alcohol wipes, clean the
build up from the cover tape application rollers. Hold the
alcohol cloth on the roller and rotate the roller 360°.
b. Repeat procedure for the other application roller.
11. Inspect the drive sprocket top idler and rubber O-Rings for any build
up from the cover tape. See the figure above.
12. If grime buildup exists on the idler and O-Rings—
CAUTION: O-Rings might be easily damaged. Handle gently to avoid
breaking them.
a. Gently remove the two O-Rings from the drive sprocket idler.
b. Using a damp cloth or a commercial wipe, remove all grime
from O-Rings.
O-rings