Introduction System Description
- 16 - Data I/O ■ 096-0465-001C
Devices in the programming sockets undergo any or all of the following
processes as determined by the job. These processes are set in TaskLink:
Continuity check
ID check
Erase
Blank check
Program
Verify programming
Read
Illegal-bit check
Functional verification operations
Secure device
Verify options such as voltage
(Optional) Mark devices
When available, devices that pass the programming and verification
operations are marked at the Laser Module for identification.
3. Load devices into the output media
Devices are moved by the PNP head to output media: trays, tubes, or
tape. Devices that fail one of the programming processes are placed into
the reject bin or reject tray.
Input and Output Options
PSV5000 System input and output options are: static tray (manual), tray
feeder (automatic), tube, and tape.
Most combinations of input and output options may be used. For
example, the PSV5000 System can be configured with input as static
tray and output as taped.
Manuals for Optional Equipment
The manuals that came with any optional equipment on your system
contain additional, more in-depth information. Some of the manuals
came in hard copy format with your PSV5000 System. Others are PDFs
installed on the Handler computer.
System Description Manuals for Optional Equipment
PSV5000 Owner’s Manual - 17 -
Figure 6: Some of the optional equipment manuals, from left to
right: Laser Marker; Automatic Tray Feeder CB (Tray Stacker).
Introduction System Description
- 18 - Data I/O ■ 096-0465-001C
PSV5000 Specifications
Specifications are without optional equipment.
FACILITIES
Supply Air Pressure clean, dry, oilfree air at
5.5
8.2 Bar (551–827 kilopascals)
(80–120 PSI)
Air Flow 85 liters/minute (3 CFM)
maximum air flow
AC Input Voltage 208240 VAC, single phase
AC Input Frequency 5060 Hz
AC Input Power (max) 15 Amps (with all options)
PSV5000 DIMENSIONS
Length, x-axis (including
monitor)
1
130 cm (51 inches)
Width (including monitor)
1
87 cm (34 inches)
Height: machine (doors closed)
then add [light tower]
153 cm (62 inches) +
[56 cm, 22 in.]
Weight (no optional
equipment), approximate
450 kg (1000 lbs.)
Environment
Operating Temperature
Hours required for
temperature stabilization
+1to +32° C (+5 to +90° F)
8 hours after transportation
Relative Humidity 35% to 90% noncondensing
Sound level 75 dB or less
OTHER
Handler PC Operating System Windows 7 OS, 32-bit
Monitor 15 inch TFT Touchscreen
1
Since the monitor arm rotates, length and width dimensions can be
adjusted
inversely, up to 10 cm (4 inches). For example, if you sub