PSV5000_OwnersManual - 第22页

Introduction ■ System Description - 18 - Da ta I/O ■ 096 - 0465 - 00 1C PSV5 000 Specificati ons Speci f ica t i ons ar e without option al equip men t. F A CI LI TI ES Suppl y Ai r Pressure clean, dry , oi l ‐ free air …

100%1 / 176
System Description Manuals for Optional Equipment
PSV5000 Owner’s Manual - 17 -
Figure 6: Some of the optional equipment manuals, from left to
right: Laser Marker; Automatic Tray Feeder CB (Tray Stacker).
Introduction System Description
- 18 - Data I/O ■ 096-0465-001C
PSV5000 Specifications
Specifications are without optional equipment.
FACILITIES
Supply Air Pressure clean, dry, oilfree air at
5.5
8.2 Bar (551–827 kilopascals)
(80–120 PSI)
Air Flow 85 liters/minute (3 CFM)
maximum air flow
AC Input Voltage 208240 VAC, single phase
AC Input Frequency 5060 Hz
AC Input Power (max) 15 Amps (with all options)
PSV5000 DIMENSIONS
Length, x-axis (including
monitor)
1
130 cm (51 inches)
Width (including monitor)
1
87 cm (34 inches)
Height: machine (doors closed)
then add [light tower]
153 cm (62 inches) +
[56 cm, 22 in.]
Weight (no optional
equipment), approximate
450 kg (1000 lbs.)
Environment
Operating Temperature
Hours required for
temperature stabilization
+1to +32° C (+5 to +90° F)
8 hours after transportation
Relative Humidity 35% to 90% noncondensing
Sound level 75 dB or less
OTHER
Handler PC Operating System Windows 7 OS, 32-bit
Monitor 15 inch TFT Touchscreen
1
Since the monitor arm rotates, length and width dimensions can be
adjusted
inversely, up to 10 cm (4 inches). For example, if you sub
tract 10 cm from
length, then add 10 cm to width.
Machine Components Safety Systems
PSV5000 Owner’s Manual - 19 -
Machine Components
The PSV5000 System has many components, or subassemblies, that
work together. Refer to the figure below to locate primary components.
Safety Systems
LIGHT TOWER
Allows monitoring the status of the PSV5000 System from a distance
while the system is processing devices. See Light Tower Interpretation in
the Operator’s Manual for a complete description of lamp colors and
significance.
GANTRY
Travels along X- and Y-axes moving the PNP head to different locations
within the work envelope. It moves devices in four axes,
X, Y, Z, and R.
The PNP head uses different sized probe tips to accommodate the great
number of device types that are available. See Installing the Correct Probe
in the Operator’s Manual. During operation, vacuum at each probe holds
a device. Vacuum sensors detect whether or not a device is present on a
probe tip.
Figure 7: The PSV5000 PNP head.
The probe picks up a device and moves it to a programming socket. To
place devices at target locations, a probe lowers, vacuum is turned off
and blow-off air is momentarily turned on.