PSV5000 Owner’s Manual - 33 -
Chapter Two 2
Setup
This chapter covers setting up the PSV5000 machine as well
as setting up equipment on the machine. This includes
optional equipment such as the Tape Output equipment, as
well as the various device media choices for running jobs,
such as setting up Static Trays or an Automatic Tray Feeder.
Machine Installation
Installation of the PSV5000 is performed by Data I/O service personnel
or an authorized distributor. After the PSV5000 arrives, ensure that
there is no damage to the exterior of the crate. Remove the PSV5000
Machine from the crate and inspect for damage that may have occurred
during shipping. If no damage is evident, unbolt the machine from the
shipping pallet.
For the intended area for PSV5000 installation see Room Considerations
on page 29.
Leveling
When the PSV5000 is at the desired location, adjust the feet to level it.
WARNING: Possible machine damage or personal injury!
Instability such as vibrating, walking, or rocking, may occur if
fewer than four of the installed feet make suitable contact with
Setup Machine Installation
- 34 - Data I/O ■ 096-0465-001C
the floor, or if the leg locknuts are not tightened against the frame. Only the
adjustable feet provided on the PSV5000 Machine should be used for
leveling. Do not use shims to assist in leveling.
Connecting Facilities
The PSV5000 requires two external services: pressurized air and
electrical power. It also allows one optional connection to an Internet via
a Network connection. These services connect to the PSV5000 Machine
at the Power Panel located on the back of the machine.
With the two required services, the machine creates all the unique
electrical voltages needed as well regulating pneumatic pressure for all
systems within the machine.
Connecting Air
The machine requires clean, dry, oil-free air from an industrial grade
compressor.
PSV5000 Air Requirements Table
Note: If the compressor cannot maintain the correct air pressure and
stable air volume, PSV5000 System performance will be affected and may
damage devices.
System
Air Volume
@ Air
Pressure
at
inlet
regulator
on
PSV5000
Supply Air
Min.
Air
Tube
Length
1
Customer supplies a
primary
filter/regulator
required between
factory compressor
and
PSV5000
2
—Metric
85 L/minute
[.084 m3/min],
tt
5.5 ±0.3 Bar
5.5 8.2 Bar
3 Meters 10 micron
3 SCFM constant
80 ±5 PSI 80 to 120 PSI 10 Feet 10 micron
1
This external air line must allow the supplied air to cool sufficiently so that water vapor in
the air
condenses and can be extracted.
2
The air filter on the Facilities Panel is a secondary filter only.