■ Applying Power f or the First Time □ (Optional ) Conne cting a n Ethe rn et Cable PSV5000 O wner ’s M anual - 37 - Applyin g Power f or the First Tim e Befo re the PSV5000 System i s turn ed on fo r the fi rst ti me, e…

Setup ■ Machine Installation
- 36 - Data I/O ■ 096-0465-001C
(Optional) Connecting an Ethernet Cable
A Network connection is on the Power Panel. Plug in an Ethernet cable.
Refer to Figure 2-1.
Network settings are described in (Optional) Network Settings on page 38
CAUTION: Possible PC virus hazard! The PSV5000 System has no
antivirus software installed from the factory. Prior to connecting to a
network, Data I/O recommends installing antivirus software.
To install antivirus software refer to (Optional) Installing Antivirus
Software on page 38.

■ Applying Power for the First Time □ (Optional) Connecting an Ethernet Cable
PSV5000 Owner’s Manual - 37 -
Applying Power for the First Time
Before the PSV5000 System is turned on for the first time, ensure the
following:
The external air line is connected, and the main air valve is open.
All E-Stop buttons are in the released (operating) positions (refer to
Emergency Stop (E-Stop) Buttons on page 1-4 for location).
All safety doors and access doors are closed.
The programmer power toggle switch on the Power Panel is ON (UP)
position.
The power switch on the Handler Computer is set to the ON position
(although it will not have power
yet). The rocker switch is ON when
tipped to the down position.
(Optional) The Socket Adapters
required for the job have been
installed on all necessary programmer sites. See Installing Socket
Adapters in the Operator’s Manual for more information. Note that
Socket Adapters can also be installed after power is on.
Note: To tighten socket adapters/boards, the recommended torque
range for FlashCORE programmer screws is 1.4 – 1.5 Newton Metre
(Nm)/12.4 – 13.3 pound force inch (lbf-in).
When satisfied, rotate the main power switch on the Power Panel to the
ON position (clockwise).
After power is applied, verify that no obvious failures or electrical
anomalies occur. Verify that the Handler Computer starts properly and
displays a network log-on dialog.
Note: If electrical or mechanical problems are noted, turn OFF the
PSV5000 System and notify Data I/O Customer Support.
At the Microsoft Log-on window, click the user profile (usually labeled
MFG) to complete the startup procedure.

Setup ■ Applying Power for the First Time
- 38 - Data I/O ■ 096-0465-001C
Shutting Down the PSV5000 System
1. Finish and Exit any job that is running.
2. (Optional) Remove all devices from the system.
3. Exit CH700 and TaskLink and any other software that you have
running.
4. Shut down the Handler Computer PC with the Windows Start
menu.
5. (Optional) Save and exit the Laser Marker software.
6. (Laser Option) Turn OFF (0) the key-switch (counterclockwise) on
the laser PC.
7. WAIT UNTIL WINDOWS COMPLETES SHUTTING DOWN, then
rotate the main power switch (on the Power Panel)
counterclockwise to the OFF (vertical) position.
If the PSV5000 Machine will not be used for several days, the shop air
should also be removed or turned off at the Power Panel. (Optional)
Padlock the main air pressure valve so that it cannot be turned back ON
while the lock is in place
(Optional) Installing Antivirus Software
The PSV5000 System has no antivirus software installed from the factory.
It is highly recommend that customers install their own antivirus
software. The software should be set to run virus scans manually rather
than at a scheduled time unless you are sure that the PSV5000 System
will not be running jobs at that time.
Note: An antivirus program may affect performance.
The PSV5000 System runs Windows 7 Professional 32-bit operating
system. Follow instructions for your antivirus software. Contact Data I/O
Service with specific questions. See Contacting Data I/O on page - 6 - (in
Preface).
(Optional) Network Settings
After starting up the PSV5000 System and logging on, double-click
Computer > Map Network Drive (Windows 7).