PSV5000_OwnersManual - 第58页
Setup ■ S etting Up In put and Output Media - 54 - Data I/O ■ 096 - 0465 - 00 1C Remember: when the reel is being taped on the TM - 50, t he trailer will be the first lengt h of empty carrier tape run before the first de…

■ Setting Up Input and Output Media □ The Tape Output Setup and Operation
PSV5000 Owner’s Manual - 53 -
Note: The recommended starting point for heat shoe air pressure is 50 PSI.
Turning the heat shoe adjuster clockwise increases the pressure.
3. After the heat sealer reaches operating temperature, set the
controller parameters, if not already set.
4. Press Start in the LCD.
5. Advance the tape using the Manual Trig button in the LCD.
6. Check the sealed tape for the desired sealed position.
7. If necessary, adjust the inner seal position by turning the inner
seal adjuster (thumb wheel) clockwise (to move the seal away from
the operator) or counterclockwise. Tighten the position lock to
secure it.
8. If necessary, adjust the outer seal position by turning the outer
seal adjuster (thumb wheel) clockwise to move the seal toward the
operator or counterclockwise (to move the seal away from the
operator). Lock the adjuster into place using the position lock
knob.
For Pressure Seal (PSA)
1. To prepare the pressure seal. Set the temperature to Room
Temperature, 25℃ .
2. Advance the tape using Manual Trig button in the LCD.
3. Adjust the inner and outer seal roller position. Align the roller
position over the strip of adhesive on either side of the PSA cover
tape. Both thumb screws have locking devices.
4. Adjust the pressure at both sealer wheels to free spinning and then
1/8 revolution tighter. Use a 2 mm hex key.
5. Advance the tape using the Manual Trig button in the LCD.
Re-adjust the seal roller pressure until the PSA adhesive is firmly
adhered to the carrier tape.
Note: Excessive roller pressure may cause carrier tape advance problems
or elongation of sprocket holes in the carrier tape.
CHECKS TO PERFORM PRIOR TO RUNNING
6. Mount an empty take-up reel on the spindle.
7. Perform a Peel Force Test Perform as many peel force tests as
needed while adjusting the sealer controls to obtain the required
seal strength.

Setup ■ Setting Up Input and Output Media
- 54 - Data I/O ■ 096-0465-001C
Remember: when the
reel is being taped on
the TM-50, the trailer
will be the first length
of empty carrier tape
run before the first
device is taped, and
the leader will be the
length of empty
carrier tape run after
the last device is
8. Create the Trailer and Leader Before beginning a production reel,
determine how long the trailer and the leader should be. Run out
enough sealed empty pockets to make the trailer that is required
for the current job.
9. Check Carrier Tape Alignment To ensure an accurate count, select
a spot on the loading track as a reference point for the first and last
devices counted.
10. Set the Counter Set the counter STOP value in the LCD to a big
number as 9,999.
Note: Use the counter on the Tape output system if desired. However, we
recommend setting this counter to zero and using the pass quantity on the
PSV5000 System to monitor quantity.
Note: When starting a job that uses Tape Output, pull the red “E-Stop/On”
button on the taping machine to start it.
PLACING DEVICES
Devices are placed by the PNP head when your job is run.
ENDING A TAPED RUN
See the PSV5000 Operators Manual or the TM-50 Tape Output System
User’s Guide.
REPLACING A FULL TAKE UP REEL
See the PSV5000 Operators Manual or the TM-50 Tape Output System
User’s Guide.
REMOVING A TAPE OUTPUT MODULE
Removal of the Tape Output Module is in the reverse order of installation.
See the instructions above.

■ Setting Up the Laser Marking Module □ Preparation:
PSV5000 Owner’s Manual - 55 -
Setting Up the Laser Marking
Module
Preparation:
1. Make sure a USB dongle for the laser has been updated.
2. Upgrade CH700 to V2.3 by installer.
3. Copy CH700.exe (v2.3.2) from
\\sol\ProjDocs\PSV5000 -
1071\Software\CH700 v2.3.2 to C:\CH700 to replace exe of v2.3.
4. Update below values in the package file
5. #134 1500 MSEC, LASER SHUTTLE MOVING TIME
6. #137 0 NUM, INCREASE OR DECREASE LASER
POWER OF CUP2 BASED ON CUP1
7. #138 0 NUM, DISTANCE BETWEEN CUP1 AND
CUP2 IN X DIRECTION
8. #139 -42000 NUM, DISTANCE BETWEEN CUP1
AND CUP2 IN Y DIRECTION
5. Start ‘MarkingMate.exe.’
6. Click a blank space on work area, and then at the Property Table,
click Work Area tab, and click Lens Correction to open the Lens
Setup dialog.