Administrative Functions Administrator Functions
- 66 - Data I/O ■ 096-0465-001C
Use the physical
keyboard instead of
the on-screen
keyboard when
entering passwords.
1. At the Main CH700 (start) window, clicking Start will open the
Security Dialog in the background. It may be obscured by other
dialogs.
2. In the Security Dialog, use the drop-down arrow to select Supervisor.
3. Enter the password.
4. Click Edit Users.
5. Type a name into the Name field.
6. Type a password into the Password field.
7. Check the box next to each stated right (privilege) for the new user.
For example: if the new user is to create or edit Package Files for
jobs, check Teach Package.
8. Click Save (the diskette image).
(Optional) Do a First Article Test
Prior to programming hundreds of devices, a newly created TaskLink
Task is tested. Follow your company’s First Article Test Plan. The two
methods discussed below are 1) Prior to creating a Package file, and 2)
after creating it.
TEST PRIOR TO CREATING A PACKAGE FILE
Outlined below is a suggested test process using Data I/O’s desktop
programmer called FlashPAK III. This method allows testing without first
having to create the Package File required for PSV5000.
1. Create a new Job for FlashPAK
1a. In TaskLink, set the Programming System to FlashPAK
(System > Select Programming System > FlashPAK).
1b. Open Task Manager and create a new Task with the Add
button.
1c. Create the Task as usual in the Edit dialog.
2. Test the new Job on FlashPAK
2a. Using the Load button, send your new Task to a PC Card,
or, if the FlashPAK is on a network, select it.
2b. Test the Task on the FlashPAK by programming a device
and verifying the results.
3. Duplicate the Job for your PSV5000 System
For help with FlashPAK
see its Operator’s Guide.
Administrator Functions (Optional) Do a First Article Test
PSV5000 Owner’s Manual - 67 -
3a. If the job passed the tests, in TaskLink Task Manager,
select the Task and click Duplicate. Enter a name and click
OK.
3b. Edit the Task so that it can be used on your PSV5000
System as follows:
I Select the Task,
II Click Edit,
III On the Task tab, use the Programming System
Type drop-down arrow to select PSV5000,
IV On the Handler Files tab, select (or create) a
Package File name,
V Click OK.
4. Run the duplicated Task on the PSV5000 System
Note: If you have the option selected to Automatically Switch Programming
Systems, (System > Options > Automatically Switch ...) then you can skip
the next step.
4a. Close Task Manager and change the programming system
to PSV5000 System (System > Select Programming
System). Re-open the Task Manager.
4b. Select the duplicated job and click Run.
Note: The Package File must be taught if it is new.
TEST AFTER CREATING A PACKAGE FILE
After a Package File is created (described in the next few headings) or it
already exists for this package type and job, then this first article test
method is best when your job includes Laser Marking.
1. Create the PSV5000 job
1a. In TaskLink, create a new job for PSV5000 Systems.
1b. Click Run (or Load) in TaskLink to start the CH700.
2. Run one device
2a. In CH700, click Start.
2b. In the Setup window, select media options as usual.
2c. At the PSV5000 workspace set up the input and output
media as usual.
2d. Click Run > Run One.
Programmers that are
not used for a particular
job can be turned off in
the CH700 Start window.
Administrative Functions Administrator Functions
- 68 - Data I/O ■ 096-0465-001C
2e. After it finishes, verify that the job passed the tests.
Note: If a programmer does not have a Socket Adapter, or an incorrect
Socket Adapter is installed, the programmer will automatically be
disabled.
(Optional) Setting TaskLink to Operator Mode
Options to add, remove, and edit Tasks are found in TaskLink’s Task
Manager Dialog when in Administrator Mode (the default). You can set
TaskLink to Operator Mode which limits actions to running and viewing
tasks in the Operator Dialog but not editing or deleting Tasks, Kits, or
Archived Jobs.
To switch between Operator Mode and Administrator Mode, see
TaskLink’s online Help.
Enhanced Yield Programming
1. Several selections on the Setup window > Options tab affect yield
that are not set in TaskLink. Administrators may wish to advise
operators regarding the setting of the Continuity Retries field and
the Fail Retries field.
2. [Automotive Performance Pak only] Optional: Determine if any of
the five utilities available with the AP Pak are required for this job.
They must be set in the CH700 Setup window > Options tab.
3. Set security rights for each operator that you doand do
notauthorize to make AP Pak changes. Changes to User Rights
are made in the Security Dialog.
Note: Only installed options are available for selection on the Options tab.
If different input media (tape or tray) is desired, the winAH400.ini file may
need to be edited. See the online Help for instructions editing the
WinAH400.int file or contact Data I/O support or an authorized technician.
Dry Run (Ignore Programmers)
(Optional) If you want to do a Dry Run or transfer devices from input
media to output media with no programming, click Ignore Programmers
so it is ON (green); the PNP head will not stop at the programmers. Laser
For more information
about Security see
Creating Security
Profiles on page 65.
For more information
on the AP Pak, see the
CH700 on-screen
Help.