PSV5000_OwnersManual - 第77页
Ad minist rator F uncti ons ≡ Monitorin g Statistic s PSV5000 O wner ’s M anual - 73 - • If an individual socket was replaced* , reset only th e row correspon ding to the rep laced socket. The R- da te (reset dat e) is…

Administrative Functions ■ Administrator Functions
- 72 - Data I/O ■ 096-0465-001C
*For FlashCORE, only
HIC Socket Adapters and
HPS Socket Adapters are
designed to
accommodate
replacement of
individual sockets on the
adapter board.
For LumenX, Socket
Adapters only have one
socket.
Figure 39: At the Statistics window, the Job Statistic file can be
viewed (Jobname.stx) as shown. When Job Statistics is selected,
Pass/Fail criteria are logged for each individual socket and
programmer listed in the left column.
Figure 40: At the Package Statistics window, statistic can be
viewed by Package Type (PackageType.sts).
RESETTING PACKAGE STATISTICS
The Package statistics displayed correspond to the Package File and
therefore to the Socket Adapter used. When a Socket Adapter is replaced
on a programmer, statistics for that Socket Adapter must be reset.
To reset Package statistics:
1. In the Statistics window, select Package Statistics in the drop-down
field in the upper left corner. Refer to the image below.
1. Click Reset in the right-most column corresponding to the
programmer on which the Socket Adapter was replaced.
• For example, if a Socket Adapter was replaced, reset all rows for
that programmer.

Administrator Functions ≡ Monitoring Statistics
PSV5000 Owner’s Manual - 73 -
• If an individual socket was replaced*, reset only the row
corresponding to the replaced socket.
The R-date (reset date) is set to the current date and statistics are all
reset to zero.
Figure 41: Resetting Package statistics. Open the Statistics
window from either the Setup window or the Run window.
STATISTICAL PROCESS CONTROL SOFTWARE
The CH700 can be set to generate a semicolon-delimited file whose fields
are described on the next page. A (customer-supplied) Statistical Control
SW can be used to import and process data output by the CH700. Or use
Data I/O’s Enhanced Statistical Software that comes with the CH700;
refer to page 89.
CAUTION: File corruption hazard! Before making any changes to your
winAH400.ini file, save a backup copy.
To generate a semicolon-delimited output file:
1. On the Handler Computer, navigate to C:\CH700 and open
winAH400.ini (with Microsoft® Notepad or IDM Computer
Solutions’s UltraEdit®).
2. Locate the section for SPC Logging. It will look like this:
[SPC Logging]
LoggingEnabled=FALSE
MaxFileSize=10485760
TempLogFile=C:\spcout.txt
3. Set the second line (LoggingEnabled) to TRUE.
4. (Optional) Edit the location of the output file at the line
“TempLogFile=...” entering the drive and path desired.
5. Save and close winAH400.ini.

Administrative Functions ■ Administrator Functions
- 74 - Data I/O ■ 096-0465-001C
Note: In the above example the SPC logging file is saved to C:\ directory. It
can, however, be saved elsewhere on the Handler Computer hard drive, or
on a networked drive if network connected.
The SPCOut.txt file contains semicolon-delimited fields. A partial list
follows:
The SPCOut.txt Field Descriptions
01 DevicesInputsystem - number of devices picked from Input
media
02 DevicesInspected - number of devices inspected by Vision system
03 InspectionQuality* - as percentage, compared with reference
vision
04 InspectionYield
05 DevicesInsertedSocket - number of devices inserted into socket
06 SocketYield
07 ProgrammerYield
08 ProgSysYield - Yield of all programmers together
09 DevicesProcessedMarker
10 MarkingYield
11 SystemThroughputExcWait - starts with first device placed,
excludes wait times.
12 SystemTotalThroughputIncWait - starts when Run starts,
includes wait times
13 SystemYield
14 AreaID - Programmer #1 = “17”, Programmer #2 = “18”, …,
Programmer #6 = “40”)
15 PosID - that is Socket #
16 TimeStamp - Date/Time of SPC log entry
17 OrderNumber - Job Name and or number
18 Package - A Package File used for the job
If the Automotive Performance Pak is installed, an extended SPC log file
(with APP enabled) would have the following delimited fields:
TimeStamp