PSV5000_OwnersManual - 第96页
Maint enance ■ Add itional F eatures - 92 - Data I/O ■ 096 - 0465 - 00 1C Make copi es of thi s chart and po st near you r work area. Maintenanc e Schedule This Maint enance Int erval Chart bel ow recommends in tervals b…

PSV5000 Owner’s Manual - 91 -
A handy sign-off chart is
at the end of this
chapter.
Chapter Four 4 —
Maintenance
Performing the maintenance procedures described in this chapter
optimizes operation of your PSV5000 System, enhances longevity by
minimizing wear and malfunctions, and reduces any downtime.
The manuals that came with any optional equipment on your
system may contain additional maintenance procedures.
Note: Only individuals trained on these procedures by Data I/O or its
representatives are qualified to perform maintenance on the PSV5000
System.
This section describes the preventive maintenance schedule for the
PSV5000 System and equipment options, with topics appearing in this
order:
Maintenance Schedule starting on the next page
Workspace, Head and Gantry on page 98
Programmers on page 119
The Laser Module on page 124
Handler Computer on page 129
Troubleshooting on page 131
Tape Output System Maintenance on page 140
Tray Feeder on page 148

Maintenance ■ Additional Features
- 92 - Data I/O ■ 096-0465-001C
Make copies of this chart
and post near your work
area.
Maintenance Schedule
This Maintenance Interval Chart below recommends intervals based on
single-shift daily usage. Information about the specified procedures and
intervals can be found on the pages referenced in the right column.
An asterisk (*) denotes optional equipment.
Date
completed
/ initials
Component
Action
(see precautions also, on page listed)
Page
Items to check Every Day
Every day Sockets
Clean with dry compressed air. Check for wear;
replace if necessary. For HIC Socket Adapters, see
more information in customer letter Cleaning HIC
Sockets (PN 983-5053) on our web site Technical
Library. This link opens the PDF which lists
cautions and suggested items, such as Cleaning
brush (PN 5655500901) and ProGold Wipes
(PN 5705500902).
page
98
Every day Input air pressure
Verify the input air pressure at the regulator is
within specifications and that it is constant, that is
the Nm3/min. [Normal Cubic Meter/min.] (SCFM )
must be stable. For specifications, see Connecting
Air on page 34.
page
34

Additional Features Maintenance Schedule
PSV5000 Owner’s Manual - 93 -
Items to check Every Week are below
Every week
Continued-
Every week
Programmers
To help ensure there are no problems with the
programmer hardware, run the programmers’
Self-test once a week at a minimum; more often is
even better. The Power-On-Self-test (POST), which
sets precision to a laser-trimmed reference, runs
when programmers are powered up. This insures
proper operation of the programmer’s voltage
sources.
CAUTION: Possible damage to programmers
and devices! DO NOT TURN AIR OR POWER OFF to
the PSV5000 Machine while a job is running.
A job must be Finished before turning OFF
compressed air or electrical power. Wait for the
gantry to park before turning OFF.
Run the Self-test by either
A) turning the PSV5000 System power OFF properly
and then ON (Shutting Down the PSV5000 System
on page 38), or
B) turning OFF only power to the programmers, and
then ON, with the Programmer Power Switch on the
Power Panel. If there is a programmer issue, a
message will display when the next job is run.
—Refer to the Operator’s Manual for switch
locations.
Every week General system
Clean surfaces of equipment and all areas in
workspace with a clean brush, cloth, or dry
compressed air.
Page
102
Every week Probe tips, on the
PNP head
• Inspect the Probe Tip to make certain it can
create a good vacuum seal on the device.
Replace if probe tip is worn, cut, or damaged.
• Clean the PNP Probe tips with alcohol wipes
(Data I/O PN 570-0410-001) or a damp cloth.
Note: Do not touch the probe tip with bare
hands. Finger oils can cause small devices to
stick.
Page
103