PSV5000_OwnersManual - 第99页

 Ad ditional F eatures  Mate ria ls R eq uired f or Prev enti ve M aint enance PSV5000 O wner ’s M anual - 95 - Every Quarter Gantry guid e rails (ev ery 100, 000 devices or every three m onths , whichev er comes first…

100%1 / 176
Maintenance Additional Features
- 94 - Data I/O ■ 096-0465-001C
Every week General system
Laser Marking*
page
124
Every week Tray Feeder*
Check the Tray Feeder for damaged or broken parts.
Check the conveyor belt and the guides for dirt,
nicks, or other signs of damage. For more
information, refer to the Tray Feeder Operator
Manual.
Items to check Every Month are below
Every
month
Tray Feeder*
Clean and Inspect the Tray Feeder.
Every
month
Supply line air filter
Check the main air filter and replace if necessary.
Drain fluid.
page
107
Every
month
Vacuum Generator
filters at PNP head
Check vacuum generator filters; replace as
necessary.
page
108
Items to check Every Three Months
Every
Quarter
Camera
Clean the Camera glass cover.
page
102
Every
Quarter
LCD Display
(Quarterly or as needed)
Clean the monitor with consumer-grade ammonia
glass cleaner. Spray window cleaner onto a soft,
lint-free cloth and wipe the screen. DO NOT APPLY
liquids directly to the screen.
DO NOT USE alcohol or industrial chemical
cleaners.
Every
Quarter
Safety doors
Clean with damp cloth.
Every
Quarter
Probe stem O-Ring
Replace the O-Ring on the probe stem.
page
103
Additional Features Materials Required for Preventive Maintenance
PSV5000 Owner’s Manual - 95 -
Every
Quarter
Gantry guide rails
(every 100,000
devices or every
three months,
whichever comes
first)
Clean and lubricate quarterly, or sooner if the
gantry becomes noisy.
Page
110
Items to check Every Six Months
6-mos. PNP head
Check; tighten if necessary.
Page
110
Every
6-mos. or
as
needed
depending
on use
Laser Marking
System*
Fume Extractor
Clean the nozzle and extraction tube.
Replace the Pre-Filter.
Replace the main filter twice yearly, or whenever the
Filter System alarm sounds and blinks the red
lamp.
Page
126
Items to check Once a Year
Every year programmers
Run conformance verification test using Data I/O’s
DAB. Or have a Data I/O Service Technician
perform the test. Customers with an APS contract
have some costs of the test covered in the
agreement.
• FlashCORE Programmers: DAB part number
910-2200-003 or higher.
LumenX Programmers: DAB Kit 910-2211-001A
or higher.
Page
119
Every year Vacuum Generator
silencers PNP head
Check vacuum generator silencers; replace as
necessary.
Page
109
* Denotes optional equipment
Materials Required for Preventive Maintenance
To perform preventive maintenance procedures on the PSV5000 System,
in general you need the following materials.
Maintenance Additional Features
- 96 - Data I/O ■ 096-0465-001C
Note: Specific items are noted at each individual procedure.
GENERALLY REQUIRED ITEMS
Lens cleaning paper (Data I/O PN 570041)
Water dampened cloth for cleaning
Isopropyl alcohol
Antistatic cleaner
Dry, compressed air
Safety goggles
Disposable protective gloves
Particle (dust) mask
SAE and metric hex socket wrenches and hex keys (Allen
Wrenches). Data I/O hex key set PNs: Metric 565-0006-001, and
Standard 565-0007-001
Screw driver sets, flat and Phillips
Metric open end wrenches for the probe tips
Shop vacuum cleaner
Self-Serve Spares Kit (page 97)
Turning off the Systems
When the PSV5000 System will not be used for several days, or before
performing a service procedure, turn OFF the system.
See Shutting Down the PSV5000 System on page 38.