Maintenance Manual - 第105页

AV131 MAINTENANCE MANUAL 5.1 I nserti on Head Un i t D79MEC- Y1-M00- A0 5.1- 2 5.1. 2 Inserti on Unit Drive Unit No. N610052015A A No. Name T y p e 1. W H a xi s origi n P914SA1 1.

100%1 / 244
AV131
MAINTENANCE MANUAL
5.1 Insertion Head Unit
D79MEC-Y1-M00-A0
5.1-1
5.1. Insertion Head Unit
D79MEC-Y1-M00-A0
5.1.1 Insertion Head
Unit No. N610052012AA
V Axis overlimit position
- side -0.45 to -0.50mm
+ side 4.00 to 5.50mm
θH Axis overlimit position
- side -95.0° to 97.0°
Head
θH
+ side 185.0° to 187.0°
No. Name Type
1. Cylinder forward detection D-A73
2. Cylinder reverse detection D-A73
3. V axis origin detection P921SA1
4. V axis (+) safety limit P921SA1
5. V axis (-) safety limit P921SA1
6.
θH axis origin detection
EE-SX870A
7.
θH axis (+) safety limit
EE-SX870A
8.
θH axis (-) safety limit
EE-SX870A
1.
2.
3.
4.
5.
6.
7.
8.
θH axis origin
θ
H axis (-) safety limit
θ
H axis (+) safety limit
AV131
MAINTENANCE MANUAL
5.1 Insertion Head Unit
D79MEC-Y1-M00-A0
5.1-2
5.1.2 Insertion Unit Drive
Unit No. N610052015AA
No. Name Type
1. WH axis origin P914SA1
1.
AV131
MAINTENANCE MANUAL
5.2 Transfer Rail
D79MEC-Y3-000-A0
5.2-1
5.2. Transfer Rail
D79MEC-Y3-000-A0
5.2.1 Transfer Rail
Unit No. N610061299AA
No. Name Type
1. PCB presence detection P919T
2. PCB presence detection P919T
3. Rail up/down cylinder return detection D-C73
4. Rail up/down cylinder traverse detection D-C73
1.
2.
3.
4.