10. RECYCLING
D79MEC-A1-000-A0
10-2
D79MEC-A1-000-A0
10. RECYCLING
This chapter describes precautions on recycling and disassembling the parts used in the AV131.
AV131
MAINTENANCE MANUAL
10.1 Precautions in Disposing of Gas Dampers
D79MEC-A1-060-A0
10.1-1
10.1. Precautions in Disposing of Gas Dampers
D79MEC-A1-060-A0
10.1.1 Removing Gas Dampers
This machine utilizes gas dampers for opening/closing the cover.
Since the gas dampers include high pressure gas, do not disassemble nor throw them in fires.
Before disposing of them, be sure to degas the cylinder.
Location
Removing Procedure
Step Operation Result, reference drawing, etc.
1.
Remove the bolts securing the gas
damper to detach the gas damper.
2.
Using a drill of the specified
diameter, punch a hole at the
position shown in the drawing to
degas the gas damper.
Do not discard it until degassing is
completed.
Bolt
Drill
AV131
MAINTENANCE MANUAL
10.1 Precautions in Disposing of Gas Dampers
D79MEC-A1-060-A0
10.1-2