Maintenance Manual - 第219页
AV131 MAINTENANCE MANUAL 11.1 M aterial Saf ety Data Sheet D79MEC- 4E-010-A 0 11 . 1 - 4 11.1. 2 Mobil V A CTR A Oi l No.2 Oil name: M o bil VA CT RA oil No.2 Manu facturer ’s nam e: Exxon M obil Corporation First Aid …

AV131
MAINTENANCE MANUAL
11.1 Material Safety Data Sheet
D79MEC-4E-010-A0
11.1-3
Safe packaging container material
36.
1. Do not pressurize empty containers. Doing so can cause explosion.
2. Do not weld, heat, drill or cut containers. Residue can catch fire with an explosion.
Disposal Consideration
37.
1. Business owners should dispose of industrial wastes by themselves, or entrust the disposal to the
specialists approved by the governor or to the local authorities responsible.
2. Do not dump into any sewers, on ground, or into any body of water.
3. Burn in a safe place in a manner where there is no possibility of hazard to others or damage to properties.
A guard must be placed.

AV131
MAINTENANCE MANUAL
11.1 Material Safety Data Sheet
D79MEC-4E-010-A0
11.1-4
11.1.2 Mobil VACTRA Oil No.2
Oil name: Mobil VACTRA oil No.2
Manufacturer’s name: Exxon Mobil Corporation
First Aid Measures
Inhalation
Keep away from the source of exposure.
Lifeguards should ensure to prevent themselves and other people from being exposed.
Wear an appropriate gear to support breathing.
If breathing problem, dizziness, or sickness is identified, or consciousness is lost, consult a physician
promptly.
If breathing has stopped, inhale oxygen using appliances, and give mouth-to-mouth respiration.
Skin contact
Flush contacted area with soap and water.
If the product is injected under the skin or any other parts in the body, consult with a physician immediately
regardless of the appearance or size of the wound.
Even if there is little or no initial symptom due to power injection, prompt treatment within several hours after
the accident can prevents the wounds from opening up.
Eye contact
Flush completely with water. Consult a physician if irritation continues.
Oral ingestion
Usually, no first-aid is required. If discomfort is felt, consult a physician.
Fire Fighting Measures
Fire extinguishing agent
Appropriate fire extinguishing agent
Loaded stream fire extinguisher, foam, dry chemical and carbon dioxide.
Inappropriate fire extinguishing agent
Water jet
Fire extinction
How to extinguish
Evacuate the danger area.
Prevent the extinguishing agent or its diluents from entering drains or water courses.
Firefighters should wear standard protective gears and use a self-contained breathing apparatus (SCBA)
inside the building or tank.
Use water spray to cool the parts that are exposed to the fire and to protect people against fire.
Harmful combustion product
Products from incomplete combustion, smoke, fume, sulfur oxides, aldehydes, and carbon oxides.
Accidental Release Measures
Notification procedure
In the event of a leakage or release, report it to relevant authorities in accordance with all applicable laws
and regulations.
Leakage control
Leak on the ground
Stop the leakage if there is no risk of danger. Use the pump or an adequate absorber to collect the leaked
oil.

AV131
MAINTENANCE MANUAL
11.1 Material Safety Data Sheet
D79MEC-4E-010-A0
11.1-5
Leak on the sea
Stop the leakage if there is no risk of danger. Deploy oil booms immediately to prevent spreading. Make sure
to give cautions to other transporters. Scoop up or soak up oil with an adequate absorber to remove it from
the water surface. Ask for specialist’s advices before using the dispersant.
Instructions on leak on the ground and the sea given here are based on the most likely scenario.
However, the measures to be taken seem to depend largely on geographical conditions, wind direction,
and temperatures. On top of these, for a leak on the sea, waves, tidal flow, and speed need to be
considered. In these cases, it is required to consult the local experts.
(Note: The measures to be taken may be specified or limited by the local regulations.)
Preventive measures for environment
Large leak
For recovery and disposal afterwards, dig a ditch at a place away from the end of leak. Prevent the oil from
flowing into channels, sewerage, underground or confined places.
Precautions in Handling and Storage
Handling
Avoid a small leakage and spillage to prevent accidents caused by slippage.
Electrostatic storage
This product accumulates static electricity.
Storage
Do not store in containers not sealed or labeled.
Disposal Consideration
Precautions in disposal are based on the state of the product in which it was supplied. Disposal of the
product must comply with the applicable laws and regulation according to the state of the product at the
time.
Disposal recommendation
It is appropriate to burn the product as fuel with a sealed burner with flame control, or with an
incineration system specially controlled to prevent hazardous combustion products from being