4
Fig. 4.1 - 1 Dimensions of the placement machine during transportation and setting up
(A) Points for attaching the fork-lift truck (fork length 1600 mm) 4
(1) Length 1587 mm
(2) Width 1921 mm
(3) Height 1836 mm
(4) Input conveyor
(5) Output conveyor
The PCB conveyor height is 830 mm ± 15 mm. 4

4 Setting up the placement machine User Manual SIPLACE F5 HM
4.1 Transport dimensions Software Version SR.408.xx 03/2006 US Edition
104
The standard PCB conveyor height is 830 mm 15 mm. The standard overall height of the
machine is 1931 mm. For a PCB conveyor height of 950 mm (SMEMA option), this gives an
overall height of 2051 mm.
4.1.1 Transport configuration
The following components are not installed when the placement system is delivered from the fac-
tory:
– Keyboard
–Monitor
– Indicator lamp
– Component trolley
– Component barcode scanner (option)
4.1.2 Safety instructions
WARNING
Æ The applicable accident prevention regulations concerning the transportation of heavy goods
must be followed.
Æ In particular, you should wear safety boots to minimize the risk of crushing your feet.
Æ When you are transporting the machine, make sure that all the feet are clear of the floor. If they
are not clear, the feet will drag along the floor and bump into obstacles. This could damage the
machine foot thread in the machine frame.
Æ Attach the pallet jack only at the points identified by (A) in Fig. 4.1 - 1).
4.1.3 Means of transport
Use a pallet jack with the following specification to carry the machine:
Fork length: min. 1600 mm
Carrying power: min. 2000 kg
Clear width between forks: min. 350 mm 4

User Manual SIPLACE F5 HM 4 Setting up the placement machine
Software Version SR.408.xx 03/2006 US Edition 4.1 Transport dimensions
105
4.1.4 Compressed air supply
4.1.4.1 Technical data
The technical data for the compressed air supply can be found in sections 3.5.2 and 3.5.3, page
76
.
4.1.4.2 Checking the compressed air supply
Check that the compressed air supply conforms to the prescribed machine specifications.
PLEASE NOTE:
The document entitled "Network configuration (electrical and compressed air) for SMD systems
on the customer's premises", item no. 00191409-xx, describes the action that can be taken to
meet the required specifications. 4
Æ Record the compressed air characteristics at the installation location.
4.1.5 Main power supply
4.1.5.1 Electrical ratings
The electrical ratings can be found in section 3.5.1, page 76.
4.1.5.2 Checking the main power supply
Check that the main power supply conforms to the prescribed machine specifications.
PLEASE NOTE:
The document entitled "Network configuration (electrical and compressed air) for SMD systems
on the customer's premises", item no. 00191409-xx, describes the action that can be taken to
meet the required specifications. 4