User Manual SIPLAC E F5 HM 5 Tasks on the m achine Software Vers ion SR.408.xx 03/2006 U S Edition 5.8 Dock ing the component trolley in or out 127 (8) Holes for the cen tering pins (9) Centerin g pin for the compo nent …

5 Tasks on the machine User Manual SIPLACE F5 HM
5.8 Docking the component trolley in or out Software Version SR.408.xx03/2006 US Edition
126
Fig. 5.8 - 2 Docking or undocking the component trolley
(1) Communication interface connector
(2) Power supply connector for the component trolley
(3) Compressed air connection
(4) Component table bed
(5) Button for raising and lowering the component table bed
(6) Actuating tube
(7) Fold-down bracket

User Manual SIPLACE F5 HM 5 Tasks on the machine
Software Version SR.408.xx 03/2006 US Edition 5.8 Docking the component trolley in or out
127
(8) Holes for the centering pins
(9) Centering pin for the component table bed
(10) Contact surfaces for the component table bed (right and left)
(11) Horizontal tensioners
(12) Movable cover that ensures that the power supply and control cables are plugged in and
removed in the correct order.
5
5.8.2 Docking out the component trolley
Æ
Click on the STOP PROCESSING PCB icon in the MAIN VIEW menu.
Æ The PCB in progress will be completed. The icons of the SINGLE FUNCTIONS menu will then
be activated.
Æ Click on the icon SINGLE FUNCTIONS GANTRY.
Æ Click on the GANTRY FUNCTIONS icon.
Æ From this menu, click on the GO TO SET-UP POSITION button.
Æ All the placement heads will move across the PCB conveyor to prevent them being damaged
when the component trolley is changed.
Æ Open protective cover of the selected gantry.
Æ Open the side screens.
Æ Open the horizontal tensioners (item 11 in Fig. 5.8 - 2)
Æ Pull the two actuating tubes (item 6 in Fig. 5.8 - 2) towards you at the same time and lift up the
bracket (item 7 in Fig. 5.8 - 2
). Thus you will lock the raised component table bed in its top end
position.
WARNING DANGER OF CRUSHING 5
When raising the component table bed, never reach into the gap between the feeders and
the used tape channel. 5
Æ Hold down the button (item 5 in Fig. 5.8 - 2) for raising the component table bed (item 4 in Fig.
5.8 - 2
) until the component table bed locks into its top end position.
Æ Unplug the component trolley power cable (item 2 in Fig. 5.8 - 2).
Æ Move the cover (item 12 in Fig. 5.8 - 2) sideways until you can unplug the control cable (item 1
in Fig. 5.8 - 2
).
Æ Unplug the component table control cable (item 1 in Fig. 5.8 - 2).
Æ Unplug the connector for the compressed air supply (item 3 in Fig. 5.8 - 2).
Æ Remove the component trolley.

5 Tasks on the machine User Manual SIPLACE F5 HM
5.8 Docking the component trolley in or out Software Version SR.408.xx03/2006 US Edition
128
5.8.3 Docking in the component trolley
PLEASE NOTE 5
Shorten the component tapes on the front end of the S feeder to approximately 1 cm before you
dock in the component trolley.
CAUTION 5
Æ Check that the placement head is outside the range of the component trolley.
Æ When docking in the component trolley, ensure that the table bed is in its top end position and
the bracket (item 7 in Fig. 5.8 - 2) is folded up.
Æ Check to see whether the left and right contact surfaces (Item 10 in Fig. 5.8 - 2) for the compo-
nent table bed are clean.
Æ Check to see that the contact surfaces on the underside of the component table bed are also
clean.
Æ CAREFULLY push the component trolley into the placement system.
Æ Attach the connector for the compressed air supply (item 3 in Fig. 5.8 - 2).
Æ Connect the control cable (item 1 in Fig. 5.8 - 2).
Æ Move the cover (item 12 in Fig. 5.8 - 2) over the control cable plug to expose the power supply
socket.
Æ Plug in the power cable (item 2 in Fig. 5.8 - 2) for the component trolley.
Æ Pull the two actuating tubes (item 6 in Fig. 5.8 - 2) towards you at the same time and then lower
the trolley bracket (item 7 in Fig. 5.8 - 2
) in order to be able to lower the component trolley.
Æ Check that the centering holes in the component table bed lie precisely over the centering pins
of the placement system.
Æ Hold down the button (item 5 in Fig. 5.8 - 2) until the component table bed locks into its top end
position.
WARNING DANGER OF CRUSHING 5
When lowering the component table bed, never reach into the gap between the feeders and
the used tape channel. 5
Æ Release the button. The component table bed will descend.
Æ Ensure that the centering pins engage in the centering holes in the component table bed and
that the component table bed is fully lowered.
Æ Lock the two horizontal tensioners (item 11 in Fig. 5.8 - 2).