00194103-01 - 第54页
2 Operational safety User Manual SIP LACE F5 HM 2.5 Safety equipment Software Version SR.408.xx 03/2006 US Edition 54 2 2.5.4 Safet y circuit s The SIPLA CE auto matic plac ement sy stem has a safety circuit wh ich is mo…

User Manual SIPLACE F5 HM 2 Operational safety
Software Version SR.408.xx 03/2006 US Edition 2.5 Safety equipment
53
2.5.3.1 Description of the functions
EMERGENCY STOP button 2
When the EMERGENCY STOP button is pressed (item 3 or item 4. in Fig. 2.5 - 4), the motor volt-
age to the gantry axes is switched off. The gantry axes are no longer powered, and thus are not
dangerous. 2
PLEASE NOTE
Placement is interrupted and can then either be continued or canceled once the system is working
correctly again. 2
Protective cover switch 2
If one of the protective covers is opened (see item 9, 10, 11 or 12 in Fig. 2.5 - 4), the gantry axes
will stop immediately. They are no longer powered, and thus are not dangerous. 2
Key switch 2
If the key switch (item 8 in Fig. 2.5 - 4) is closed (position I), the PCB control can be tested while
the protective covers are open. The gantry axes are no longer powered, and thus are not danger-
ous. 2
PLEASE NOTE
The key switch remains open for normal mode, i.e. in the 0 position. 2
WARNING
The protective covers must only be opened, with the key switch closed (position I), by appropri-
ately qualified and trained personnel. 2
2.5.3.2 Status messages and the action required
The following displays may appear in placement mode. If they appear, carry out the action spec-
ified in the third column. 2

2 Operational safety User Manual SIPLACE F5 HM
2.5 Safety equipment Software Version SR.408.xx 03/2006 US Edition
54
2
2.5.4 Safety circuits
The SIPLACE automatic placement system has a safety circuit which is monitored by the protec-
tive contactor combination K1. The protective contactor combination is contained in the power
supply unit (see item 14 in Fig. 2.5 - 4
).
WARNING
Automatic placement systems from the SIPLACE family are powered with 3 x 400 VAC (3 x 208
VAC for the U.S.A. version) ± 5 %, 50/60 Hz main power voltage.
This means that some parts of the system carry potentially lethal voltages - even when switched
off at the main power switch. Death, serious injury or considerable damage may result if these au-
tomatic placement systems are handled incorrectly.
Always follow the applicable accident prevention and DIN regulations (particularly EN 60204,
part 1) and the applicable regulations in your own country.
The guard over the power supply must ONLY be opened by appropriately qualified and trained
personnel. 2
Protective contactor combination K1 monitors the following circuits:
EMERGENCY STOP circuit, safety circuits for the component trolleys or waffle-pack changer,
protective cover switches and the enable software signal
K1 is triggered if any of these functions fail. The main power voltage to the heavy current trans-
former that supplies the gantry axis motors, the star motor, the lifting tables and the used tape
cutter will be interrupted. The DP or Z axes for the placement heads are still supplied with
30VDC. The next diagram illustrates the various statuses of K1 and their effects on the axes and
the PCB conveyor components.
Status Display on screen Action required
EMERGENCY
STOP button
pressed
EMERGENCY STOP
pressed ...
Machine stopped.
Release button
Release the pressed EMERGENCY
STOP button (pos. 3 or 4 in Fig. 2.5 - 4
)
Press start button Press the white Start button (pos. 2 or 5 in
Fig. 2.5 - 4
)
Protective
cover open
Close the cover Close the protective cover (item 9, 10, 11
or 12 in Fig. 2.5 - 4
)
Press start button Press the white Start button (pos. 2 or 5 in
Fig. 2.5 - 4
)
Tab. 2.5 - 1 Screen display when the EMERGENCY STOP button is pressed or the protective cover is open

User Manual SIPLACE F5 HM 2 Operational safety
Software Version SR.408.xx 03/2006 US Edition 2.5 Safety equipment
55
Fig. 2.5 - 5 Safety circuits
Start button pressed
No
No
Yes
No
No
Yes
Yes
No
2
Active
K1*) Yes
K2**) Yes
Voltage
Y axis 155 VDC
X axis 155 VDC
Star axis 100 VDC
DP axis 30 VDC
Z axis 30 VDC
Active
PCB conveyor Yes
Lifting table Yes
PCB clamp Yes
Width adjustment Yes
PCB stopper Yes
Used tape cutter Yes
Yes
2
Active
K1*) No
K2** Yes
Voltage
Y axis 0 VDC
X axis 0 VDC
Star axis 0 VDC
DP axis 30 VDC
Z axis 30 VDC
Active
PCB conveyor Yes
Lifting table No
PCB clamp No
Width adjustment Yes
PCB stopper No
Used tape cutter No
2
Active
K1*) No
K2**) No
Voltage
Y axis 0 VDC
X axis 0 VDC
Star axis 0 VDC
DP axis 30 VDC
Z axis 30 VDC
Active
PCB conveyor No
Lifting table No
PCB clamp No
Width adjustment No
PCB stopper No
Used tape cutter No
*) K1 protective contactor combination
**) K2 contactor
Yes
Compressed air min. 0.51
MPa (5.1 bar)?
EMERGENCY STOP button
pressed?
Protective cover open ?
Component
trolley safety circuit
interrupted?
Key switch closed (position
I)?