00194103-01 - 第75页

User Manual SIPLAC E F5 HM 3 Technical data Software Vers ion SR.408.xx 03/2006 U S Edition 3.4 Electrical and pneuma tic connection points 75 DANGER The placeme nt system i s supplie d with 3 x 400 V AC or 3 x 208 V AC …

100%1 / 230
3 Technical data User Manual SIPLACE F5 HM
3.4 Electrical and pneumatic connection points Software Version SR.408.xx 03/2006 US Edition
74
3.4 Electrical and pneumatic connection points
3
Fig. 3.4 - 1 Electrical and pneumatic connection points on the machine
(1) Compressed air unit
(2) Connection for compressed air line
(3) Main power filter Z1
(4) Hole for power cable
(5) Service socket
(6) Compressed air connection for component trolley
(7) Power connection for the component trolley
(8) Communications connection for the component trolley
(9) LAN connection in the control unit
(10) Main power switch
User Manual SIPLACE F5 HM 3 Technical data
Software Version SR.408.xx 03/2006 US Edition 3.4 Electrical and pneumatic connection points
75
DANGER
The placement system is supplied with 3 x 400 VAC or 3 x 208 VAC US version) ± 5%, 50/60 Hz
main power voltage. This means that some parts of the system carry potentially lethal voltages
- even when switched off at the main power switch. Death, serious injury or considerable damage
may result if this automatic placement system is handled incorrectly. 3
WARNING
Never disconnect compressed air lines while they are pressurized. Risk of injury. 3
3 Technical data User Manual SIPLACE F5 HM
3.5 Technical data – Ratings Software Version SR.408.xx 03/2006 US Edition
76
3.5 Technical data – Ratings
3.5.1 Technical data – Electrical ratings
3
3.5.2 Technical data – Compressed air supply
3
3.5.3 Technical data – Compressed air specification
Maximum particle size by density, based on ISO/DIS 8573-1 (class 1) 3
3.5.4 Technical data – Noise emissions
3
3.5.5 Technical data – permissible ambient factors
3
Supply voltage 3 x 400 VAC ± 5 %; 50/60 Hz (Europe)
3 x 208 VAC ± 5 %; 50/60 Hz (U.S.A.)
Fuses 3 x 16 A (3 x 400 VAC, 3 x 208 VAC)
Nominal apparent power 1.3 kVA
Rated current consumption 3.4 A / 3 x 400 VAC
Power failure Max. 20 msec
Compressed air pressure min. 5.5 bar, max. 8 bar
Compressed air consumption 300 st. l/min. (6-segment Collect&Place head)
400 st. l/min. (12-segment Collect&Place head)
Operating pressure Set to 5.2 bar ± 0.1 bar
Connection 1/2"
Particle size 0.1 µm
Particle density 0.1 mg/m³
Maximum oil content (class 1) Particle density 0.01 mg/m³
Pressure dewpoint (class 4) Dewpoint +3°
Max. noise generated 74dB(A)
Room temperature Between 15°C and 35°C