00194103-01 - 第84页
3 Technical data User Manual S IPLACE F5 H M 3.7 Controls S oftware Version SR.408.xx 03/2006 US Edition 84 3.7.3.1 Controls on the i nput and output sides of t he placement sys tem The contr ols on the inp ut and output…

User Manual SIPLACE F5 HM 3 Technical data
Software Version SR.408.xx 03/2006 US Edition 3.7 Controls
83
touch screen monitor with a resolution of 1024 x 768 pixels provides the screen display. The ul-
tra-flat IBM-compatible PC keyboard incorporates a trackball for controlling the mouse. 3
Indicator lamp 3
The sequence of colors is white - green - white. These lamps are used to signal operating sta-
tuses and malfunctions of the placement system. 3
Component barcode scanner (option) 3
There is a compartment for the Datalogic DL 910 component barcode scanner between the mon-
itor and keyboard. The barcode scanner enables the components to be set up and topped up
quickly and reliably. 3
3.7.3 Ergonomic arrangement of the controls
Figure 3.7 - 1 on page 81 provides an overview of the position of the controls. They are subdivided
into the following groups: 3
Operating panel on the PCB input side with 3
– Start button
– Stop button
– EMERGENCY STOP button
– Main switch (on the left-hand side)
Operating panel on the PCB output side with 3
– EMERGENCY STOP button
– Start button
– Stop button
– Component counter
–Key switch
Console on the central crossbeam with 3
– Station computer
– Touchscreen
– Keyboard and
– Component barcode scanner (option)
3 Technical data User Manual SIPLACE F5 HM
3.7 Controls Software Version SR.408.xx 03/2006 US Edition
84
3.7.3.1 Controls on the input and output sides of the placement system
The controls on the input and output sides of the placement machine perform identical functions.3
EMERGENCY STOP buttons, Start and Stop buttons 3
There is an EMERGENCY STOP button, a Start button and a Stop button on both the input and
output sides of the PCB conveyor. This arrangement was adopted for the EMERGENCY STOP
buttons because it enables them to be reached quickly and easily from any position. 3
In addition, it is important to have an unrestricted view of the placement heads and placement
area during maintenance, servicing and setting up work in order to be able to check all the oper-
ations carried out inside the machine. This particularly important during testing phases or when
starting single functions, for example. 3
Key switch 3
The key switch is located on the operating panel on the PCB output belt. It is only needed for
setting up and servicing work so, for reasons of efficiency, it is positioned near the Start and Stop
buttons. 3
Main power switch 3
The main switch is part of the power supply unit, so it is positioned on the left-hand side of the
PCB input belt. It is located here because it is only needed for servicing and maintenance work
and is therefore not subject to frequent use. 3
3.7.3.2 Controls on the placement system console
Station computer, monitor and keyboard 3
The station computer, monitor and keyboard are all mounted on the console. They are arranged
so that any person who is at least 1.60 m tall can work comfortably and efficiently. 3
Component barcode scanner (option) 3
The two component trolleys for supplying components are arranged on the right and left of the
placement system. For this reason, the component barcode scanner is also located in the central
console. It enables the operators to work comfortably and efficiently during the component set-
up and filling checks. 3

User Manual SIPLACE F5 HM 3 Technical data
Software Version SR.408.xx 03/2006 US Edition 3.8 Gantry
85
3.8 Gantry
3.8.1 Position of the gantry
3
Fig. 3.8 - 1 Position of the gantry
(1) Gantry
3
The gantry system consists of two functional groups 3
– X axis and
–Y axis
3