00197279-03_SM_Glue-Feeder_EN - 第69页

Replacing Spare Parts 3.17.1 Manometer (Dispenser) Manometer Service Manual SIPLACE Glue Feeder 69 3.17.1.2 3 . 1 7 . 1 . 2 F it t in g t h e M a n o m e t e r ( D is p e n s e r ) Fitting the Manometer (Dispenser) ► Car…

100%1 / 96
Replacing Spare Parts
Manometer 3.17.1 Manometer (Dispenser)
68 Service Manual SIPLACE Glue Feeder
Remove the large brass nut with the straight push-fit
connector. Use two fork wrenches for this:
a size 14 fork wrench for below, to hold the screw,
a size 11 fork wrench for above, to loosen the brass
nut.
Once you have removed the brass nut (1), pull the fix
-
ture bracket sideways and off the manometer. (2)
Carefully press the manometer a little out of the cover
plate. (1)
Carefully pull the manometer fully out of the cover
plate. (2)
Replacing Spare Parts
3.17.1 Manometer (Dispenser) Manometer
Service Manual SIPLACE Glue Feeder 69
3.17.1.2
3.17.1.2 Fitting the Manometer (Dispenser)
Fitting the Manometer (Dispenser)
Carefully insert the manometer as far as possible into
the cover plate. (1)
Align the manometer vertically. (2)
Push the fixture bracket from the side onto the
manometer. (1)
Push the fixture bracket forwards, as far as possible
(end stop) and align it so that it is straight. (2)
Fasten the large brass nut with the straight push-fit
connector. Use two fork wrenches for this:
a size 14 fork wrench for below, to hold the screw,
a size 11 fork wrench for above, to tighten the brass
nut.
Replacing Spare Parts
Manometer 3.17.1 Manometer (Dispenser)
70 Service Manual SIPLACE Glue Feeder
Fasten the fixture bracket with the two marked nuts.
Use a size 7 fork wrench for this.
Fit the cover plate with the two manometers onto the
front of the glue feeder frame.
Make sure that the manometer (dispenser) is at the
top.
Fasten the cover plate with the 4 screws marked. Use
a size 1.5 Allen key for this.
Carefully place the glue feeder down on its left side.
Connect the hose marked with adhesive tape to the
top manometer (dispenser).
Connect the other hose to the bottom manometer
(cartridge).
Remove the adhesive tape from the marked hose.