00197279-03_SM_Glue-Feeder_EN - 第71页
Replacing Spare Parts 3.17.2 Manometer (Cartridge) Manometer Service Manual SIPLACE Glue Feeder 71 3.17.2 3 . 1 7 . 2 M a n o m e t e r ( C a r t r id g e ) Manometer (Cartridge) Required spare parts Manometer 4K8-4P ass…

Replacing Spare Parts
Manometer 3.17.1 Manometer (Dispenser)
70 Service Manual SIPLACE Glue Feeder
► Fasten the fixture bracket with the two marked nuts.
Use a size 7 fork wrench for this.
► Fit the cover plate with the two manometers onto the
front of the glue feeder frame.
Make sure that the manometer (dispenser) is at the
top.
► Fasten the cover plate with the 4 screws marked. Use
a size 1.5 Allen key for this.
► Carefully place the glue feeder down on its left side.
► Connect the hose marked with adhesive tape to the
top manometer (dispenser).
► Connect the other hose to the bottom manometer
(cartridge).
► Remove the adhesive tape from the marked hose.

Replacing Spare Parts
3.17.2 Manometer (Cartridge) Manometer
Service Manual SIPLACE Glue Feeder 71
3.17.2
3.17.2 Manometer (Cartridge)
Manometer (Cartridge)
Required spare parts
Manometer 4K8-4P assembly, item no. 03094560-xx
Required tools
▪ Phillips screwdriver
▪ Allen key, size 1.5
▪ Open-ended wrench, size 7
▪ Open-ended wrench, size 11
▪ Open-ended wrench, size 14
3.17.2.1
3.17.2.1 Removing the Manometer (Cartridge)
Removing the Manometer (Cartridge)
The manometer (cartridge) is removed using the same procedure as that for removing the manometer
(dispenser), see "3.17.1.1 Removing the Manometer (Dispenser)" [ ➙ 66].
Only difference:
remove the bottom manometer instead of the top one.
3.17.2.2
3.17.2.2 Fitting the Manometer (Cartridge)
Fitting the Manometer (Cartridge)
The manometer (cartridge) is fitted using the same procedure as that for fitting the manometer (dispens
-
er), see "3.17.1.2 Fitting the Manometer (Dispenser)" [ ➙ 69].
Only difference:
fit the bottom manometer instead of the top one.
► Carefully place the glue feeder down on its right side.
► Fasten the marked screw. Use a Phillips screwdriver
for this.
► Now fasten the right side cover (see "3.8.2 Fitting the
Right Side Cover" [ ➙ 21]).

Replacing Spare Parts
Solenoid valve 3.18.1 Removing the Solenoid Valve
72 Service Manual SIPLACE Glue Feeder
3.18
3.18 Solenoid valve
Solenoid valve
Required spare parts
Solenoid valve CPE14-M1BH-3GL-QS-6, item no. 00385552-xx
Required tools
▪ Phillips screwdriver
▪ Allen key, size 2.5
3.18.1
3.18.1 Removing the Solenoid Valve
Removing the Solenoid Valve
► Remove the right side cover (see "3.8.1 Removing
the Right Side Cover" [ ➙ 21])
► Remove the two screws which fasten the solenoid
valve to the frame. Use a size 2.5 Allen key for this.
► Open the lock and pull the hose out of the right con
-
nection on the T-connector.