Replacing Spare Parts Handle assembly 3.24.2 Fitting the Handle Assembly 94 Service Manual SIPLACE Glue Feeder ► Fasten the marked Allen screw. Use a size 2.5 Allen key for this. ► Run the flat ribbon cable as shown in t…

100%1 / 96
Replacing Spare Parts
3.24.2 Fitting the Handle Assembly Handle assembly
Service Manual SIPLACE Glue Feeder 93
As shown in the diagram, plug the pressure control
valve into the glue feeder frame.
Fasten the pressure control valve with a nut. Use a
size 24 fork wrench for this. (1)
Fit the cover as far as possible onto the pressure con
-
trol valve. (2)
Fasten the right side cover (see "3.8.2 Fitting the
Right Side Cover" [ ➙ 21])
Fasten the handle using the two marked Torx screws.
Use a size T8 TORX screwdriver for this.
Replacing Spare Parts
Handle assembly 3.24.2 Fitting the Handle Assembly
94 Service Manual SIPLACE Glue Feeder
Fasten the marked Allen screw. Use a size 2.5 Allen
key for this.
Run the flat ribbon cable as shown in the diagram.
Carefully fold the flat ribbon cable as marked in the di
-
agram.
Make sure that the blue surface at the end of the ca
-
ble is at the top.
Use double-sided adhesive band to fix the flat ribbon
cable at the marked place to the glue feeder frame.
Insert the flat ribbon cable as far as possible into the
connection.
Make sure that the blue surface at the end of the ca
-
ble is at the top and that the flat ribbon cable lies
straight in the connection.
Swing the lock on the connection down.
Make sure that the flat ribbon cable is fitted firmly in
the connection. Tug gently on the cable to check.
Check again whether the flat ribbon cable is fitted
straight in the connection.
If necessary, open the connection and correct the po
-
sition of the flat ribbon cable before closing the con
-
nection again.
Fasten the left side cover (see "3.7.2 Fitting the Left
Side Cover" [ ➙ 20].