00195089-0102_AI_Vakuumpumpe_X-Serie_60X_DE EN - 第100页

Assembly Instructions SIPLACE Vacuum Pump Ausgabe 07/2006 96 Fig. 2.9.4 Eingang DI6 : Wire the black cable from X1 6 ra_2 to input DI6 on the “CAN In /Out module 2” (see Fig. 2.9.4 ). 2 Don’t mix up the cable s! 2 2 : Wi…

100%1 / 130
Assembly Instructions SIPLACE Vacuum Pump
Ausgabe 07/2006
95
Fig. 2.9.3 Plug X16 for the vacuum pump’s control cable
: Secure plug X16 as shown in Fig. 2.9.3.
2
Assembly Instructions SIPLACE Vacuum Pump
Ausgabe 07/2006
96
Fig. 2.9.4 Eingang DI6
: Wire the black cable from X16 ra_2 to input DI6 on the “CAN In/Out module 2” (see Fig. 2.9.4 ).
2
Don’t mix up the cables! 2
2
: Wire the black cable from relay K2_A1 to output DO6 on the “CAN In/Out module 2” (see Fig.
2.9.5).
Fig. 2.9.5 Output DO6
Assembly Instructions SIPLACE Vacuum Pump
Ausgabe 07/2006
97
Fig. 2.9.6 Masse
: Wire the white cable from relay K2_A2 to the ground in terminal block X1ra_0V (see Fig. 2.9.6)
.
Fig. 2.9.7 Supply voltage 24V (for plug X16)
: Wire the orange cable from plug X16ra_3 to terminal block X1ra_24V (see Fig. 2.9.5).
2
Both wires on relay K2_13 (X16ra_4) and K2_14 (X16ra_3) are needed to control the vacuum
pump. 2
2
: Connect the control cable “cable power vacuum pump” (03049005-) to X16. Control and/or mo-
nitoring of the vacuum pump is only available starting with SW 603.