00195089-0102_AI_Vakuumpumpe_X-Serie_60X_DE EN - 第71页

Assembly Instructions SIPLACE Vacuum Pump 2 Assembl y Instructions for Vacuum Pump SIPLACE X Series Ausgabe 07/2006 67 sensitive ground leakage circuit breaker in system s with drive regulato rs with a three-phas e power…

100%1 / 130
2 Assembly Instructions for Vacuum Pump SIPLACE X Series Assembly Instructions SIPLACE Vacuum Pump
Ausgabe 07/2006
66
b) Placement head C&P20 Item no: 03008827-03 2
2.3 Necessary Parts
Retrofit Kit Vacuum Pump Operation C&P20 Item no. 119790
Retrofit Kit Vacuum Pump Operation X4 Item no. 119791
Retrofit Kit Vacuum Pump Operation X3 Item no. 119792
Retrofit Kit Vacuum Pump Operation X2 Item no. 119793
Vacuum Pump X series 220V (3 ~ 400V) Item no. 119794
Vacuum Pump X series 110V (3 ~ 208V) Item no. 119795
Retrofit Kit Vacuum Pump Oper
ation C&P6/12
Item no. 119796
2.4 Necessary Tools
flat wrench 10
set of Allen wrenches
set of Philips head screwdrivers
wire cutter
tube gripper
release tool for Q8 Item no. 03047090-
2.5 Safety instructions
2.5.1 Safety Instructions for Vacuum Pump
In general, for the vacuum pump all manufacturer’s instructions – in addition to the safety
instructions in Paragraph 2.5.2 – regarding safety, particularly all
instructions regarding installation
and operation, must be followed. 2
When the vacuum pump type 2SH7 503 from Gardner Denver Elmo Technology GmbH is turned
on and off, it
can trip the ground leakage circuit breaker installed in the building's power supply.2
In that case Gardner Denver Elmo Technology recommends the use of a universal current-
Assembly Instructions SIPLACE Vacuum Pump 2 Assembly Instructions for Vacuum Pump SIPLACE X Series
Ausgabe 07/2006
67
sensitive ground leakage circuit breaker in systems with drive regulators with a three-phase power
socket (L1/L2/L3). Further information on this subject can be found in the operating instructions
for the vacuum pump system. 2
The vacuum pump should be connected to a separate circuit breaker. 2
When connecting the vacuum pump note that in ad
di
tion to the standard power cable a grounding
wire should be connected. This requires a suitable “grounding rail” in the customer’s power
system. 2
2.5.2 General safety instructions
WARNING
Comply with the higher ranking "Safety Instructions" in Chapter "Operational Safety" in the User
Manual and Service Manual 2
The placement machines SIPLACE are powered by mains voltage.
Portions of the system are therefore conducting dangero
us electricity, inside the machine even
while the master switch is turned off.
Death, serious injury or considerable damage may result if these automatic placement systems
are h
andled incorrectly.
After you have properly carried out the shut-down
of the operating system:
Before all work the machine must be turned off at the main switch a
nd isolated from the mains. In
addition, the compressed air supply must be turned off at the main valve of the compressed air
unit in the machine base and the compressed air lines must be bled by actuating the needle valve
at the compressed air unit.
Danger: For anyone wearing a heart pacemaker it is not permitted to work near linear motors, as
descr
ibed in detail in the User Manual and the Service Manual, Chapter "Special Safety Instruc-
tions when working in vivinty of powerful magnetic fields" .
Obey the applicable accident prevention regulations, DIN stan
dards and special safety codes of
your country at all times. DIN EN 60204 must be adhered to during all work inside the machine
base.
Follow the instructions regarding residual voltages in Chapter "Operational Safety".
Comply with regulations on ESDs (see Chapter "Operational Safety").
During the work of retrofitting secure the machine conscientiously against other personnel and
pre
vent it from being turned back on without authorization, as described in the User Manual in the
chapter "Locking the Machine...".
There is additional, higher risk of accident when working with the SITEST program.
The SITEST program is only to be started by personnel who are authorized to do so. 2
2
2 Assembly Instructions for Vacuum Pump SIPLACE X Series Assembly Instructions SIPLACE Vacuum Pump
Ausgabe 07/2006
68
2.5.3 ESD-safety
2
Pay attention to Collect&Place placement head ESD-safety:
The plates inside the Collect&Place placement
head are very sensitive. 2
2
2.5.4 Definitions
2
Please note 2
2
2
2
Tip 2
2
2
2
Caution 2