2.6.1 Retrofit Kits in Detail
* Upgrade Kit Vacuum Pump Operation X-Series03047470- 2
1 pc Vacuum distributor SIPLACE X series 03034629- 2
15 M Siphon and pressure hose Di 32 HELISPRING 00368279- 2
1 pc Y connector HELICONNECT 948 032 00368697- 2
6 pc Hose clamp DIN 3017 NW 32 - 50 00363127- 2
4 pc Vacuum distributor hose 03038843- 2
4 pc Sealing plug QSC-12H 03015210- 2
4 pc Sealing plug QSC-16H 03051739- 2
1 pc Relay with plug 03048999- 2
1 pc Cable: power vacuum pump 03049005- 2
1 pc End clamp without screws 6mm 249-116 00356396- 2
5 pc Cable tie W=4.8mm L=186mm TYB-25M 00805142- 2
1 pc Release tool for Q8 03047090- 2
1 pc Vacuum supply base components 03038773- 2
2
* Upgrade Kit Vacuum 1P and 2P U 03038195- 2
1 pc Hose 1, vacuum 1P 03038472- 2
1 pc Hose 2, vacuum 1P 03038473- 2
1 pc Connector, dual hose 03038107- 2
1 pc Dual hose cable drag chain 1P 03033626- 2
1 pc Clamping device 1 03032860- 2
1 pc DIN 125-A 3.2-140HV-St 00095471- 2
1 pc DIN912-M3 x 30-8.8 hex. socket head cap screw 00845020- 2
1 pc Vacuum connection block 1 03038493- 2
1 pc Vacuum connection block 2 03038494- 2
4 pc Vacuum distributor hose 03038843- 2
2
* Upgrade Kit Vakuumversorgung 2P G 03039015- 2
1 pc Hose 1, vacuum 2P G 03039017- 2
1 pc Hose 2, vacuum 2P G 03039018- 2
1 pc Vacuum supply base components 2P G 03045680- 2
1 pc Connector, dual hose 03038107- 2
1 pc Dual hose cable drag chain 1P 03033626- 2
1 pc Clamping device 1 03032860- 2
1 pc DIN 125-A 3.2-140HV-St 00095471- 2
1 pc DIN912-M3 x 30-8.8 00845020- 2
1 pc Vacuum connection block 1 03038493- 2
1 pc Vacuum connection block 2 03038494- 2
Assembly Instructions SIPLACE Vacuum Pump
Ausgabe 07/2006
71
2.7 Pneumatics and Vacuum Supply
Retrofitting a placement machine with 4 C&P20 heads for vacuum pump operation is shown
below. 2
2
A maximum of 4 placement machines can be connected to a vacuum pump with connecting
cables. The limitations regarding the C&P20 heads must be taken into account, however. 2
Preconditions (based on machine config
uration): see Chapter 2.2. 2
2
A placement machine with mixed operation (vacuum and compressed air) doesn’t make sense if
you have a vacuum pump at your disposal. Therefore only the retrofitting of all portals to vacuum
pump operation is described. 2
2
2
If a Twin Head is used, the pneumatic supply, portal distributor and cable drag chain of that portal
should never be retrofitted! Otherwise the Twin Head may not function any more. 2
Assembly Instructions SIPLACE Vacuum Pump
Ausgabe 07/2006
72
Fig. 2.7.1 Pneumatic unit (in starting position)
(1) Portal distributor (top)
(2) Plate for vacuum distributor block (on the side)
(3) Pneumatic unit (bottom)
2
2