Assembly Instructions SIPLACE Vacuum Pump Ausgabe 07/2006 75 Depending on the port al configuration, the following dummy plug s must be removed: 2 2 A portal with T win Head cannot be retrofitted. Leave the dummy plug fo…

100%1 / 130
Assembly Instructions SIPLACE Vacuum Pump
Ausgabe 07/2006
74
: Open the power supply’s door
(the connections for Portal 1 and 2 are located here)
Fig. 2.7.3 Portal distributor, power supply side (with dummy plug Portal 1+2, starting position)
: Close the main compressed air shut-off valve.
: Close the shut-off valve for the placement machine.
: Wait until the pressure has dissipated.
Assembly Instructions SIPLACE Vacuum Pump
Ausgabe 07/2006
75
Depending on the portal configuration, the following dummy plugs must be removed: 2
2
A portal with Twin Head cannot be retrofitted. Leave the dummy plug for the corresponding portal
in the distributor. 2
2
X2: Plug for Portal 1 (power supply side) and Portal 3 (pneumatics side)
X3: Plug for Portal 1 + 2 (power supply side) und Portal 3 (pneumatics side)
X4: Plug for Portal 1 + 2 (power supply side) und Portal 3 + 4 (pneumatics side)
: To do so, press the blue rings (see Fig. 2.7.3) in th
e dir
ection of the axis and remove the cor-
responding dummy plug.
Fig. 2.7.4 Hoses run at manufacturer’s (here for Portal 1+2)
: Pull the hoses down until you can see the labelling.
Assembly Instructions SIPLACE Vacuum Pump
Ausgabe 07/2006
76
Fig. 2.7.5 Hose labelling (here for Portal 3+4)
Fig. 2.7.6 Retrofitted pneumatic distributor for Portal 1+2 (facing side)
: Plug the hoses into the portal distributor, based on the labelling and the machine configuration
(both for Portal 1+2 and Portal 3+4).