2 Retrofit instructions Pneumatic maintenance unit SIPLACE D1/D2 / S-27 HM Pneumatic unit 05/2007 Edition 14 2.5 Retrofit An additional adapter plate with air exhaust drill must be fitted between 5/2 way valve and the ba…

Pneumatic unit 2 Retrofit instructions Pneumatic maintenance unit SIPLACE D1/D2 / S-27 HM
05/2007 Edition
13
2.4 Safety instructions
WARNING
The safety instructions from the “Operational safety” chapter of the user manual and servicing in-
structions take precedence over these instructions. 2
The SIPLACE placement machines are supplied with main power voltage.
Consequently parts of these systems carry dangerous voltages! This voltage is present at certain
modules inside the machine base, even when the machine is switched off at the main power
switch.
Incorrect handling of the placement machine or touching live parts of the machine can result in
death or severe injury, and considerable damage to equipment.
BEFORE starting any work, shut down the operating system correctly, then switch the machine
OFF at the main power switch and disconnect from the main power supply. In addition, the com-
pressed air supply must be switched off at the compressed air unit's main valve in the machine
base and vented by actuating the needle valve on the compressed air unit.
There is DANGER for heart pacemaker wearers in the vicinity of the linear motors, as described
in detail in the "Special safety instructions for working in the vicinity of strong magnetic fields"
section of the user manual and service manual.
Always follow the accident prevention regulations, DIN or other standards and special safety
rules applicable in your country.
Pay attention to the information concerning residual voltages in the Operational Safety chapter.
Follow the ESD regulations as described in the operational safety section of the operating
instructions.
During the retrofit, always secure the machine to prevent access by other people and to prevent
it being switched on again. The procedure is described in the "Lock out and tag out procedure"
section of the user manual.
Working with the SITEST program further increases the risk of accident.
The SITEST program must only be used by authorized and trained personnel.
2
2.4.1 Definitions
2
Please note 2
2
2
2

2 Retrofit instructions Pneumatic maintenance unit SIPLACE D1/D2 / S-27 HM Pneumatic unit
05/2007 Edition
14
2.5 Retrofit
An additional adapter plate with air exhaust drill must be fitted between 5/2 way valve and the base
of the compressed air unit. 2
: Switch off the placement machine at the main switch.
: Turn off the main compressed air supply.
: Assemble the adapter plate with exhaust drill inclusively two sealings between the 5/2 way
valve and the base of the compressed air unit (2 screws M3 x 35 mm).
2
The sidewise exhaust drill has to be at the same side as the electrical connection!
2
2
sealing
sealing
distance plate
5/2 way valve
adapter plate with
exhaust drill
electrical connection
electrical connection
5/2 way valve
exhaust drill

Pneumatic unit 2 Retrofit instructions Pneumatic maintenance unit SIPLACE D1/D2 / S-27 HM
05/2007 Edition
15
: Open the main compressed air supply.
: Switch on the placement system at the main switch.
: Execute a reference run.
2
: Check the correct function after the assembly:
By opening the protective covers you must hear a loud noise (fizz).
: For further control pull off one of the four air hoses at the distributor.
The hoses are switches parallel.
When function is correct no noticeable pressure must be at this hose.
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Air distributor