00193903-02 - 第23页
SIPLACE HF-series / D3 8 External power supply for SIPLACE HF-Series / D3 component trolley 06/2006 Edition 23 7.1 T echnical data 7.1.1 Compressed air Input pressure: max. 10 bar (= 1000 kPa) 7 Output pressure: 2.5 bar …

8 External power supply for SIPLACE HF-Series / D3 component trolley SIPLACE HF-series / D3
06/2006 Edition
22
6.0.2 Changing the fuse
6
Fig. 7 Power switch with fuses
7
: Switch the power switch (3) to OFF and make sure that the mains plug is not plugged in the
unit.
: Push up the snap-fit closure (9) to release and pull out the black plastic insert (7) with the fuses.
: Remove and check the two fuses (5) and replace them if necessary.
: Only use type 5x20 mm / medium time-lag 6.3 Amp fuses (e.g. 03011614-01).
: Push the black plastic insert (7) with the fuses back into the unit until the snap-fit closure lat-
ches into place.
7

SIPLACE HF-series / D3 8 External power supply for SIPLACE HF-Series / D3 component trolley
06/2006 Edition
23
7.1 Technical data
7.1.1 Compressed air
Input pressure: max. 10 bar (= 1000 kPa) 7
Output pressure: 2.5 bar (= 250 kPa) 7
7.1.2 Mains voltage
7.1.3 Weights / dimensions
Weight: 4.3 kg 7
Dimensions: W x D x H = 180 x 360 x 210 mm 7
7
7
Voltage
88 - 264 VAC
Frequency
47...63 Hz
Nominal current
5A / 115 VAC 2,5A / 230 VAC
Fuse
6,3A MT (medium time-lag)
8 External power supply for SIPLACE HF-Series / D3 component trolley SIPLACE HF-series / D3
06/2006 Edition
24