3 Introduction and Basic Concepts User Manual HS-50
3.3 User Interface - Views and Menus Software Version SR.501.xx 12/99 Issue US
124
t IIt
Control Modes: 3
Stand alone (for test purposes only) 3
This control mode allows you to load a cluster (placement program) for test and service purposes
from the station computer using the menu item "New cluster..." .
The necessary data must be located on the station computer’s hard disk. 3
GEM Host 3
In this control mode, clusters can only be specified by the host computer.
The necessary data must be located on the host computer’s hard disk. 3
NOTE
This setting must be activated if you want to download cluster data from the host computer to the
station computer via the GEM interface. The procedure for doing this is described in Chapter. 13.
This control mode cannot be set in the current software version since the "GEM Interface" option
has not yet been implemented. 3
Line Computer 3
If a cluster has been prespecified at the station, all the necessary associated data is loaded from
the line computer. The data must be located on the line computer’s hard disk. 3
NOTE
By default, clusters and set-ups should be prespecified by the line computer.
If the line computer is powered down via "Shut down" and then rebooted, all the connected sta-
tions must also be rebooted. 3
SIPLACE Pro 3
This control mode cannot be set in the current software version. 3
3
Å Activate the radio button for the required control mode.
Å Click OK to make your settings active.
User Manual HS-50 3 Introduction and Basic Concepts
Software Version SR.501.xx 12/99 Issue US 3.3 User Interface - Views and Menus
125
t IIt
New cluster... 3
In the "Stand alone" control mode, you can load the data for a selected cluster from the station
computer’s hard disk.
Å Click the menu item New cluster...
Å Now enter the name of the required cluster in the displayed text box and click OK to confirm.
The cluster data is now loaded.
NOTE
The data, including the fiducial and package form data, of the last cluster successfully prespecified
by the line computer, is now saved on the station computer’s hard disk under the cluster name
"AKTUELL" and can be loaded by entering this name. 3
Software ... 3
This menu item is used to activate the test commands (test functions) for checking a variety of
machine components. 3
NOTE
This menu item can only be called from the "Service" access level. 3
DANGER
Settings for test commands and test command execution should be performed by service engi-
neers only. 3
Å Click the menu item Software ...
The following window is opened.
3 Introduction and Basic Concepts User Manual HS-50
3.3 User Interface - Views and Menus Software Version SR.501.xx 12/99 Issue US
126
t IIt
3
Å Select the tab corresponding to the required machine component and activate/deactivate the
test commands by clicking the corresponding checkboxes.
Å Click Accept to set the software options.
NOTE
When the station is rebooted, the software options are reset to their original settings. 3
Cycle mode ... Alt+t 3
You use this menu item to switch the station to cycle mode (e.g. to localize errors). 3
Å Click the menu item Cycle mode... or press the key combination ALT+t. The "Cycle mode"
settings box is opened.
Å Click the On radio button to activate cycle mode or the Off radio button to deactivate it.
Å Click the OK button. Cycle mode is now either activated or deactivated.
NOTE
In cycle mode, you must press the Start button on the machine for every operating step. 3