00191369-02 - 第149页

User Manual HS-50 4 Placement Functions Software Vers ion SR.501.xx 12/99 Issue US 4.3 Feeders 149 t I I t 4.3.1.4 Refilling All Empty T r acks of a Location Å Click on the button for the lo cation that is to be confirme…

100%1 / 414
4 Placement Functions User Manual HS-50
4.3 Feeders Software Version SR.501.xx 12/99 Issue US
148
t IIt
NOTE
If the "-" character is entered in this column, then this means that no barcode is specified for
the corresponding component. You can therefore manually refill the corresponding track us-
ing "Refill tracks" even if the "Component verification with barcode" option is active (see Sec-
tion 4.3.1.5). 4
4
4.3.1.2 Functions in the "Empty Tracks" View
4
Location 1 4
Confirms that all tracks for location 1 are full. 4
Location 2 4
Confirms that all tracks for location 2 are full. 4
Selected track 4
Confirms that the feeder on the selected track for location 1 or 2 is full. 4
Location 3 4
Confirms that all tracks for location 3 are full. 4
Location 4 4
Confirms that all tracks for location 4 are full. 4
Selected track 4
Confirms that the feeder on the selected track for location 3 or 4 is full. 4
4
4.3.1.3 "Refilling" Empty Tracks
Å Select the entry in the table or the track that is to be confirmed as being "refilled". The line se-
lected is highlighted in light blue in the table and the "Selected track" button is active.
Å Click on the Selected track button when the feeder in this track has been refilled with compo-
nents.
The track is then considered full and the entry is deleted from the list of empty tracks.
The "Selected track" button is not active thereafter.
User Manual HS-50 4 Placement Functions
Software Version SR.501.xx 12/99 Issue US 4.3 Feeders
149
t IIt
4.3.1.4 Refilling All Empty Tracks of a Location
Å Click on the button for the location that is to be confirmed as being "refilled", e.g. Location 1.
All tracks of this location are then considered refilled and the corresponding entries for the
empty tracks in this location are deleted from the list of empty tracks.
The button for the location is not active thereafter.
4.3.1.5 Refilling Empty Track When the "Component Verification With Barcode"
Option is Active
When the "Component verification with barcode" option is active, then empty tracks can normally
only be confirmed as having been "refilled" in the manner described in Section 4.3.1.5
.
The tracks containing components without
component barcodes are an exception. You can man-
ually "refill" here even if the "Component verification with barcode" option is active. 4
Å Select the entry in the table (see Fig. 4.3 - 2) for an empty track that contains components with-
out barcodes (see the note on page 148).
The "Selected track" button is active.
Å Click on the Selected track button when the feeder in this track has been refilled.
The "Selected track" button is not active thereafter.
4 Placement Functions User Manual HS-50
4.3 Feeders Software Version SR.501.xx 12/99 Issue US
150
t IIt
4.3.2 "Omit components" view
The “Omit components” function is used to deliberately leave out components on selected tracks
when processing the PCB.
This may be necessary, for example, in order to check component placement when introducing
the first PCB of a new cluster. When the PCB is produced, any components set to “Omit compo-
nents” will then be ignored on all the tracks on which they are set up. The incomplete PCBs will
then be transported to the output belt, where they must be removed manually.
When this function is activated, the specified components will be omitted from all subsequent
PCBs until you reset the function.
4
Å Click on the icon.
The “Omit components” view will appear (see Fig.
4.3 - 3
).
4
Fig. 4.3 - 3 “Omit components” view
PLEASE NOTE
The “Omit components” function cannot be used at the “Operator” access level.
4