User Manual HS-50 5 Single Functions Software Version S R.501.xx 12/99 Issue US 5.2 Single functions, Gantry 169 t I I t 5.2.6 "Nozzle changer configuration revolver head" screen 5 Å In the c urrent screen for …

5 Single Functions User Manual HS-50
5.2 Single functions, Gantry Software Version SR.501.xx 12/99 Issue US
168
t IIt
RV head indexing 5
This function is used to move the revolver head.
Å Click the RV head indexing button.
The revolver head is moved on one segment.
The current positions of the segments are shown in the graphic.
Confirm 5
This function allows you to confirm that a nozzle has been changed (without nozzle changer).
To change a nozzle without a nozzle changer you must perform the operation by hand. You can
only change the nozzle on one segment at a time because the segment must be in the
changeover position. By turning the head in a clockwise fashion you can bring each segment in
turn to the changeover position.
5
Å In the table, find the segment for which the nozzle is to be changed.
Å Click the RV head indexing button as often as required to bring the required segment round
until it is displayed in the changeover position (marked with an arrow).
The table entry for this segment is now highlighted in light blue (see Fig. 5.2 - 5
).
Å Remove the nozzle by hand and replace it with a nozzle of the type shown in the "Preset" co-
lumn.
Å Click the Confirm button.
The change is confirmed. The entries in the columns "Actual" and "Preset" agree. The new no-
zzle configuration is saved to the machine data.

User Manual HS-50 5 Single Functions
Software Version SR.501.xx 12/99 Issue US 5.2 Single functions, Gantry
169
t IIt
5.2.6 "Nozzle changer configuration revolver head" screen
5
Å In the current screen for the single function for Gantry x, click the symbol .
NOTE
The nozzle changer must be installed and configured in the machine options. 5
The user interface is switched to the "Nozzle changer configuration revolver head" screen (see
Fig. 5.2 - 6
). 5
5
Fig. 5.2 - 6 "Nozzle changer configuration revolver head" screen

5 Single Functions User Manual HS-50
5.2 Single functions, Gantry Software Version SR.501.xx 12/99 Issue US
170
t IIt
5.2.6.1 General comments
In the "Nozzle changer configuration revolver head" screen there are functions which allow you to
adjust and confirm the nozzle configuration for the individual magazines in the nozzle changer.
Click on the appropriate button to carry out the required function.
The nozzle changer configuration is displayed in the table in the display.
5
Conditions for changing the set-up of the nozzle changer
Remember the following points when changing the set-up: 5
– The magazines may only be filled when all nozzles on the revolver head have been returned
to their magazines.
– Magazines may only contain nozzles of one type.
– The maximum number of nozzles per magazine is 12.
– The maximum number of magazines on a nozzle changer is 5.
– The magazines must be filled outside the machine and must only ever be changed in their en-
tirety.
– To remove and load nozzles you must open the lock. Once you have finished, you must then
close the lock again.
Meaning of the entries in the table in the display
– Magazine
Number of the magazine
– Number
Number of nozzles in the magazine
– Actual
Type of nozzles currently in the magazine
– Preset
If the type of nozzle currently in the magazine is not the same as shown in this column, then it
is to be changed
– To change
An arrow ( <== ) in this column indicates that the nozzle type currently in the magazine ("Ac-
tual" column) must be changed for the nozzle type shown in the "Preset" column.