7 What should you do ... User Manual HS -50 7.1 Switching on the SIPLACE line Software V ersion SR.501.xx 12 /99 Issue US 322 t I I t 7.1 Switching on the SIPLACE line 7.1. 1 Sw itch ing on the lin e com puter / starting…

100%1 / 414
User Manual HS-50 7 What should you do ...
Software Version SR.501.xx 12/99 Issue US
321
t IIt
7 What should you do ...
This chapter contains a number of subjects that are intended to help you during your daily work
on a SIPLACE line.
For example, you are provided with preventative measures that you can take to minimize the down
time on the machine to obtain the highest possible level of efficiency for the SIPLACE line during
production. 7
In addition, the tasks of the operator and of the line engineer are described in an operator and line
engineer profile, respectively, in this chapter. 7
7
7 What should you do ... User Manual HS-50
7.1 Switching on the SIPLACE line Software Version SR.501.xx 12/99 Issue US
322
t IIt
7.1 Switching on the SIPLACE line
7.1.1 Switching on the line computer / starting the user interface of the line
computer program
Å Switch on the uninterruptible power supply (UPS).
The line computer software is uploaded.
The login dialog window appears on the screen after approximately 2 minutes.
Å Enter
plr
in the "login" box and confirm your entry by pressing the RETURN key.
Å Enter the password in the "Password" box and press the RETURN key. If no password is re-
quired, then just press the RETURN key
The desktop (starting window) will appear on screen after approximately 3 minutes with the
overlying login box.
Å Enter the user name defined for your user account in the "User" box, and enter the correspond-
ing password in the "Password" box.
Å Click on Ok to confirm. The functions of the line computer program can now be executed ac-
cording to your access rights.
7.1.2 What you should check before switching on the stations
ATTENTION
Carry out the steps described in the following before you switch on the stations. 7
Å Check to make sure that the stations are connected to power and to the compressed air supply.
Å Carry out a visual inspection of the stations. In particular, make sure that there are no obstruc-
tions in the traveling range of the gantries.
Å Make sure that the z-axes of all the heads are in the top end position.
Å Close the feeder covers and the protective covers.
Å Make sure that there is no diskette in the floppy drive of the station computer.
User Manual HS-50 7 What should you do ...
Software Version SR.501.xx 12/99 Issue US 7.1 Switching on the SIPLACE line
323
t IIt
7.1.3 Switching on the station / starting the user interface of the station computer
program
ATTENTION
Switch on the station only after the desktop is displayed on the line computer monitor. Otherwise,
communication problems may occur. 7
Å Switch on the station on the main switch and check to see if the manometer displays the re-
quired operating pressure after you have switched the station on.
The station computer software is uploaded. When the line computer is connected and commu-
nication is error-free, the Main view of the station computer user interface appears for the "Op-
erator" user class after approximately 2 minutes (see Fig. 7.1 - 1
).
7
Fig. 7.1 - 1 Main view after loading the station computer software
NOTE
The current state of the station is displayed in the status field in the "State" line, and the action you
are to execute is displayed in the "Action:" line (see Fig. 7.1 - 1). 7