00191369-02 - 第381页

User Manual HS-50 11 S tation extensions / hardware Software Vers ion SR.501.xx 12/99 Issue US 11.1 HS-50 nozzle c hanger 381 t I I t 1 1 S t ation extensions / hardware 1 1.1 HS-5 0 nozzle ch anger 1 1.1.1 Overview The …

100%1 / 414
10 Component handling User Manual HS-50
10.6 Component changeover tables Software Version SR.501.xx 12/99 Issue US
380
t IIt
10.6.3 Docking the component changeover table
WARNING 10
Check that the placement head is outside the range of the component changeover table.
CAUTION 10
When docking the component table, ensure that the table bed is in its top end position and the
clip (item 5) is folded up.
Å Carefully push the component changeover table into the placement system.
Å Plug the connecting cable for the component changeover table into the socket (item 2) in the
placement system.
Å Open the flap over the push-button for raising the component changeover table.
Å Hold down the button (item 1) until the component table bed reaches its top end position.
Å Check that the centering holes in the component table bed are exactly over the centering pins
on the placement system.
Å Then fold down the clip (item 5) of the component changeover table to lower the component
table bed.
Å Ensure that the centering pins engage in the centering holes in the component table bed and
that the component table bed is fully lowered.
Å Close the flap over the push-button (item 1).
Å Close the protective cover.
10
User Manual HS-50 11 Station extensions / hardware
Software Version SR.501.xx 12/99 Issue US 11.1 HS-50 nozzle changer
381
t IIt
11 Station extensions / hardware
11.1 HS-50 nozzle changer
11.1.1 Overview
The placement system is supplied as standard with four revolver heads and four nozzle changers.
As an option, a second nozzle changer can be installed for each revolver head. 11
The nozzle changer consists of at least one, and up to five magazines, each with 12 nozzle ga-
rages (see Fig. 11.1 - 1
). The magazines are seated on a common support and each magazine is
centered using two parallel pins and fixed in place with clips. 11
11.1.2 Technical data
11
Nozzle changer for the revolver head
Dimensions (length x width x height) 472.5 mm x 64 mm x 90 mm
Number of nozzle garages Min. 12 / max. 60
Nozzle types 9xx
Time required to open and close the locking plate < 200 ms
Pneumatic circuit Air line 5.3 bar
Tab. 11.1 - 1
11 Station extensions / hardware User Manual HS-50
11.1 HS-50 nozzle changer Software Version SR.501.xx 12/99 Issue US
382
t IIt
11
Fig. 11.1 - 1 Position of the nozzle changer
Key to Fig. 11.1 - 1
(1) Used tape guide channel (2) Nozzle discarding device
(3) Nozzle changer (4) Nozzle magazines
(5) Location for optional 2nd nozzle changer
(6) Container for discarded nozzles