1.12 Overview of the modules - gantries
1.12.1 Position of the gantries
1
Fig. 1.12 - 1 Position of the gantries
(1)Gantry 1 (sector 1)
(2)Gantry 2 (sector 2)
(3)Gantry 3 (sector 3)
(4)Gantry 4 (sector 4)
1
The gantry system consists of two functional groups 1
–X-axis
–Y-axis
1
1 Introduction User Manual HS-50
1.12 Overview of the modules - gantries Software Version SR.501.xx 12/99 Issue US
40
t IIt
1.12.2 Structure of the X-axis
1
Fig. 1.12 - 2 Structure of the X-axis
The X-axis essentially consists of the following main modules: 1
gantry arm (1)
head mount (2)
linear measuring system (3)
X-axis guide system (4)
X-axis three-phase AC servomotor (5)
The head mount holds the following components 1
sub-gantry camera (camera for the PCB vision system)
head board
measuring head for the X-axis measuring system
revolver placement head
User Manual HS-50 1 Introduction
Software Version SR.501.xx 12/99 Issue US 1.12 Overview of the modules - gantries
41
t IIt
1.12.3 Technical data for the X-axis
1.12.4 Structure of the Y-axis
1
Fig. 1.12 - 3 Structure of the Y-axis
Drive Three-phase AC servomotor/toothed belt
Maximum speed 2.5 m/sec.
Traversing path 375 mm
Distance measuring system Metal linear scale
Measured length 400 mm
Scale length 420 mm
Resolution 1 µm
(1) Gantry 1 (2) Gantry 2
(3) Gantry 3 (4) Gantry 4
(5) Permanent magnet (6) Guide system
(7) Measuring system (8) Adapter plate