SA_HF_intern_0194307-02_eng - 第10页
2 Safe ty Sa fet y In s tr ucti o n s SIPL ACE HF-Ser ies Safety Instruction s for the Power Supply 2-4 0019 43 07- 02 Is su e 1 1/ 2004 Copy ri gh t © 2 004 S ie m ens 2.1.4 Safety Instructions for the P ower Supply DAN…

SIPLACE HF-Series
Safety Instructions for Work on the Cutting Device
Safety
Safety Instructions
2
Copyright © 2004 Siemens 00194307-02 Issue 11/2004 2-3
DANGER
If you wish to work on the tape cutter, you must disconnect the machine from the mains supply and compressed
air supply.
Wait until the operating pressure has dropped to 0 MPa.
Wear appropriately thick protective gloves when working near the blades/the tape deflector!
There is a high risk of injury from stationary blades and moveable blades and from the tape deflector of the cutter,
even when the machine has been turned off!
Never reach into the pneumatic cutter from below or into the empty-tape duct from above, not even to resolve a
problem (e.g. when tape is jammed).
WARNING
Wear appropriately thick protective gloves.
When removing the cutter, hold it only on the left and right, on the outside.
Never support the cutter on your body (e.g. on your knee or thighs). Do not place your feet under the cutter.
You could injure yourself severely or at least damage your clothing!
Make sure that no one can injure themselves on the cutter after it has been dismantled!

2
Safety
Safety Instructions
SIPLACE HF-Series
Safety Instructions for the Power Supply
2-4
00194307-02 Issue 11/2004 Copyright © 2004 Siemens
2.1.4 Safety Instructions for the Power Supply
DANGER
The machine is supplied with 3 x 400 V~ (or 3 x 204 V~ / 3 x 230 V~ / 3 x 380 V~ / 3 x 415 V~) ± 5 %, 50/60 Hz mains
voltage.
Consequently, parts of the system carry potentially lethal voltages, even when it is switched off at the main switch.
Incorrect handling of the placement system can therefore result in death, severe injury or considerable damage to
equipment.
Measurements and repairs must always be carried out by appropriately qualified personnel.
Always follow the safety instructions in the Siplace HF Operating Instructions.
Always follow the applicable accident prevention and VDE regulations (particularly DIN EN 60 204, part 1) or the
regulations specific to your country.
Before starting any repairs, switch off at the main switch and disconnect the placement system from the main
power supply.
Always secure the machine against unauthorized reactivation. If these instructions are not followed, it is possible to
touch live parts, which could result in death or severe injury.

SIPLACE HF-Series
Safety Instructions for the Compressed Air Supply
Safety
Safety Instructions
2
Copyright © 2004 Siemens 00194307-02 Issue 11/2004 2-5
Exchanging components
End all placement operations on the placement system.
Shut down the Windows NT operating system correctly, otherwise problems may occur when restarting or data may
be lost.
Switch the placement system off at the main switch.
Disconnect the placement system from the main power supply.
Switch off the machine and attach warnings signs to indicate that service work is in progress.
2.1.5 Safety Instructions for the Compressed Air Supply
CAUTION
When the machine is switched on, do not use the shutoff valve to interrupt the compressed air supply for more than 30
minutes. If you need to shut off the pneumatic system for longer, in order to carry out maintenance or servicing work, you
must switch the placement system off at the main switch and disconnect it from the power supply.
WARNING
NEVER detach compressed air lines while they are still pressurized. Risk of injury!